674 1311

Cited 0 times in

혈청단백 전기영동 및 면역고정 전기영동 검사의 국내 외부정도관리 평가

DC Field Value Language
dc.contributor.author이상국-
dc.contributor.author임정훈-
dc.date.accessioned2022-05-09T17:23:39Z-
dc.date.available2022-05-09T17:23:39Z-
dc.date.issued2022-04-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/188543-
dc.description.abstractIn Korea, many laboratories rely on inter-laboratory proficiency testing for external quality control of serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE). Therefore, we conducted an external quality assessment in 12 clinical laboratories. Five test samples were prepared by pooling residual samples together in our laboratory according to the SPEP pattern or the existence of monoclonal proteins, and then aliquoting them. Each clinical laboratory carried out SPEP and IFE tests, quantified each fraction and monoclonal protein (if present), and produced the interpretation reports according to the method of each laboratory. Monoclonal protein was detected in two of the five test samples, and the detection of monoclonal proteins and the isotyping results were consistent in all participating institutions. There were no significant variations in the quantities of albumin, alpha-1, and -2 globulin fractions, and the whole beta-gamma region. However, the values of beta-1, -2, and gamma globulin fractions differed significantly, and there was a large variation in the reported monoclonal protein concentrations. The quantitative values obtained using the tangent skimming method were much lower than those obtained using the other methods. In this study, the interpretation reports were generally consistent, but the quantitative values were different between the participating laboratories. This is the first study to approach the external quality assessment of SPEP and IFE in Korea. Further studies are required to establish external quality control management for these tests.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisherKorean Society for Laboratory Medicine-
dc.relation.isPartOfLaboratory Medicine Online-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title혈청단백 전기영동 및 면역고정 전기영동 검사의 국내 외부정도관리 평가-
dc.title.alternativeExternal Quality Assessment of Serum Protein and Immunofixation Electrophoresis in Korea-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthor조주영-
dc.contributor.googleauthor이동현-
dc.contributor.googleauthor임정훈-
dc.contributor.googleauthor이상국-
dc.identifier.doi10.47429/lmo.2022.12.2.122-
dc.contributor.localIdA02810-
dc.contributor.localIdA04654-
dc.relation.journalcodeJ02151-
dc.identifier.eissn2093-6338-
dc.subject.keywordSerum protein electrophoresis-
dc.subject.keywordImmunofixation electrophoresis-
dc.subject.keywordQuantitation-
dc.subject.keywordMonoclonal protein-
dc.subject.keywordExternal quality assessment-
dc.contributor.alternativeNameLee, Sang Guk-
dc.contributor.affiliatedAuthor이상국-
dc.contributor.affiliatedAuthor임정훈-
dc.citation.volume12-
dc.citation.number2-
dc.citation.startPage122-
dc.citation.endPage128-
dc.identifier.bibliographicCitationLaboratory Medicine Online, Vol.12(2) : 122-128, 2022-04-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.