261 492

Cited 0 times in

Cited 4 times in

Performance Evaluation of Deformable Image Registration Algorithms Using Computed Tomography of Multiple Lung Metastases

DC Field Value Language
dc.contributor.author김동욱-
dc.contributor.author김지훈-
dc.contributor.author김진성-
dc.contributor.author김호진-
dc.contributor.author박광우-
dc.contributor.author장지석-
dc.contributor.author한민철-
dc.contributor.author한수철-
dc.contributor.author홍채선-
dc.contributor.author김진아-
dc.date.accessioned2022-05-09T16:57:02Z-
dc.date.available2022-05-09T16:57:02Z-
dc.date.issued2022-01-
dc.identifier.issn1533-0346-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/188297-
dc.description.abstractPurpose: Various deformable image registration (DIR) methods have been used to evaluate organ deformations in 4-dimensional computed tomography (4D CT) images scanned during the respiratory motions of a patient. This study assesses the performance of 10 DIR algorithms using 4D CT images of 5 patients with fiducial markers (FMs) implanted during the postoperative radiosurgery of multiple lung metastases. Methods: To evaluate DIR algorithms, 4D CT images of 5 patients were used, and ground-truths of FMs and tumors were generated by physicians based on their medical expertise. The positions of FMs and tumors in each 4D CT phase image were determined using 10 DIR algorithms, and the deformed results were compared with ground-truth data. Results: The target registration errors (TREs) between the FM positions estimated by optical flow algorithms and the ground-truth ranged from 1.82 ± 1.05 to 1.98 ± 1.17 mm, which is within the uncertainty of the ground-truth position. Two algorithm groups, namely, optical flow and demons, were used to estimate tumor positions with TREs ranging from 1.29 ± 1.21 to 1.78 ± 1.75 mm. With respect to the deformed position for tumors, for the 2 DIR algorithm groups, the maximum differences of the deformed positions for gross tumor volume tracking were approximately 4.55 to 7.55 times higher than the mean differences. Errors caused by the aforementioned difference in the Hounsfield unit values were also observed. Conclusions: We quantitatively evaluated 10 DIR algorithms using 4D CT images of 5 patients and compared the results with ground-truth data. The optical flow algorithms showed reasonable FM-tracking results in patient 4D CT images. The iterative optical flow method delivered the best performance in this study. With respect to the tumor volume, the optical flow and demons algorithms delivered the best performance.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherSAGE-
dc.relation.isPartOfTECHNOLOGY IN CANCER RESEARCH & TREATMENT-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAlgorithms-
dc.subject.MESHFiducial Markers-
dc.subject.MESHFour-Dimensional Computed Tomography / methods-
dc.subject.MESHHumans-
dc.subject.MESHImage Processing, Computer-Assisted / methods-
dc.subject.MESHLung Neoplasms* / diagnostic imaging-
dc.subject.MESHRadiosurgery*-
dc.titlePerformance Evaluation of Deformable Image Registration Algorithms Using Computed Tomography of Multiple Lung Metastases-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorMin Cheol Han-
dc.contributor.googleauthorJihun Kim-
dc.contributor.googleauthorChae-Seon Hong-
dc.contributor.googleauthorKyung Hwan Chang-
dc.contributor.googleauthorSu Chul Han-
dc.contributor.googleauthorKwangwoo Park-
dc.contributor.googleauthorDong Wook Kim-
dc.contributor.googleauthorHojin Kim-
dc.contributor.googleauthorJee Suk Chang-
dc.contributor.googleauthorJina Kim-
dc.contributor.googleauthorSunsuk Kye-
dc.contributor.googleauthorRyeong Hwang Park-
dc.contributor.googleauthorYoonsun Chung-
dc.contributor.googleauthorJin Sung Kim-
dc.identifier.doi10.1177/15330338221078464-
dc.contributor.localIdA05710-
dc.contributor.localIdA05823-
dc.contributor.localIdA04548-
dc.contributor.localIdA05970-
dc.contributor.localIdA01432-
dc.contributor.localIdA04658-
dc.contributor.localIdA05870-
dc.contributor.localIdA05942-
dc.contributor.localIdA05846-
dc.relation.journalcodeJ02714-
dc.identifier.eissn1533-0338-
dc.identifier.pmid35167403-
dc.subject.keyworddeformable image registration-
dc.subject.keywordfiducial marker tracking-
dc.subject.keywordlung deformation-
dc.subject.keywordmultiple lung metastases-
dc.subject.keywordtumor tracking-
dc.contributor.alternativeNameKim, Dong Wook-
dc.contributor.affiliatedAuthor김동욱-
dc.contributor.affiliatedAuthor김지훈-
dc.contributor.affiliatedAuthor김진성-
dc.contributor.affiliatedAuthor김호진-
dc.contributor.affiliatedAuthor박광우-
dc.contributor.affiliatedAuthor장지석-
dc.contributor.affiliatedAuthor한민철-
dc.contributor.affiliatedAuthor한수철-
dc.contributor.affiliatedAuthor홍채선-
dc.citation.volume21-
dc.citation.startPage15330338221078464-
dc.identifier.bibliographicCitationTECHNOLOGY IN CANCER RESEARCH & TREATMENT, Vol.21 : 15330338221078464, 2022-01-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.