Analysis of keratometric measurements in accordance with axial length in an aged population

Authors
 Sung Uk Han  ;  Soyoung Ryu  ;  Hyunjean Jung  ;  Hyunmin Ahn  ;  Sangyeop Kim  ;  Ikhyun Jun  ;  Kyoung Yul Seo  ;  Tae-Im Kim 
Citation
 SCIENTIFIC REPORTS, Vol.12(1) : 4087, 2022-03 
Journal Title
SCIENTIFIC REPORTS
Issue Date
2022-03
MeSH
Aged ; Astigmatism* / diagnosis ; Cornea / diagnostic imaging ; Corneal Diseases* ; Corneal Topography ; Humans ; Prospective Studies ; Reproducibility of Results ; Retrospective Studies
Abstract
To investigate keratometric measurements according to axial length in an aged population. Patients requiring cataract surgery with keratometric measurements from four different ophthalmic devices (autorefractor/keratometer, Scheimpflug imaging, corneal topography/ray-tracing aberrometry, and partial coherence interferometry) between January 2016 and March 2021 were reviewed retrospectively. Cases for which four ophthalmic devices were deployed in the same order a day were included in this investigation. The corneal curvature of the flattest and steepest meridian, mean corneal curvature, corneal astigmatism, steepest axis location, and axial length were evaluated. In total, 250 eyes (137 patients) were included in the analysis. A negative correlation was found between mean corneal curvature and axial length, with correlation coefficients of 0.587, 0.592, 0.588, 0.591, 0.588, and 0.562 for autorefractor/keratometer, Scheimpflug imaging, corneal topography/ray-tracing aberrometry, partial coherence interferometry, total corneal refractive power of Scheimpflug imaging, and simulated keratometry of corneal topography/ray-tracing aberrometry measurements, respectively. No statistically significant differences were found for corneal astigmatism according to axial length. In axial length group of less than 26.0 mm, negative correlation was found between axial length and mean frontal corneal curvature while no correlation was found between axial length and corneal astigmatism. All four ophthalmic devices showed good inter-device reliability for mean corneal curvature but not corneal astigmatism.
Files in This Item:
T202200715.pdf Download
DOI
10.1038/s41598-022-08194-0
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Tae-Im(김태임) ORCID logo https://orcid.org/0000-0001-6414-3842
Seo, Kyoung Yul(서경률) ORCID logo https://orcid.org/0000-0002-9855-1980
Ahn, Hyunmin(안현민)
Jun, Ik Hyun(전익현) ORCID logo https://orcid.org/0000-0002-2160-1679
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/188271
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links