155 250

Cited 0 times in

Serial line multiplexing method based on bipolar pulse for PET

DC Field Value Language
dc.contributor.author김규범-
dc.date.accessioned2022-05-09T16:43:07Z-
dc.date.available2022-05-09T16:43:07Z-
dc.date.issued2021-11-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/188154-
dc.description.abstractAlthough the individual channel readout method can improve the performance of PET detectors with pixelated photo-sensors, such as silicon photomultiplier (SiPM), this method leads to a significant increase in the number of readout channels. In this study, we proposed a novel multiplexing method that could effectively reduce the number of readout channels to reduce system complexity and development cost. The proposed multiplexing circuit was designed to generate bipolar pulses with different zero-crossing points by adjusting the time constant of the high-pass filter connected to each channel of a pixelated photo-sensor. The channel position of the detected gamma-ray was identified by estimating the width between the rising edge and the zero-crossing point of the bipolar pulse. In order to evaluate the performance of the proposed multiplexing circuit, four detector blocks, each consisting of a 4 × 4 array of 3 mm × 3 mm × 20 mm LYSO and a 4 × 4 SiPM array, were constructed. The average energy resolution was 13.2 ± 1.1% for all 64 crystal pixels and each pixel position was accurately identified. A coincidence timing resolution was 580 ± 12 ps. The experimental results indicated that the novel multiplexing method proposed in this study is able to effectively reduce the number of readout channels while maintaining accurate position identification with good energy and timing performance. In addition, it could be useful for the development of PET systems consisting of a large number of pixelated detectors.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherKorea Nuclear Society-
dc.relation.isPartOfNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleSerial line multiplexing method based on bipolar pulse for PET-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Neurosurgery (신경외과학교실)-
dc.contributor.googleauthorYeonkyeong Kim-
dc.contributor.googleauthorYong Choi-
dc.contributor.googleauthorKyu Bom Kim-
dc.contributor.googleauthorHyuntae Leem-
dc.contributor.googleauthorJin Ho Jung-
dc.identifier.doi10.1016/j.net.2021.05.032-
dc.contributor.localIdA06016-
dc.relation.journalcodeJ03972-
dc.subject.keywordMultiplexing method-
dc.subject.keywordSerial line multiplexing-
dc.subject.keywordSiPM-
dc.subject.keywordPET-
dc.contributor.alternativeNameKim, Kyu Bom-
dc.contributor.affiliatedAuthor김규범-
dc.citation.volume53-
dc.citation.number11-
dc.citation.startPage3790-
dc.citation.endPage3797-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, Vol.53(11) : 3790-3797, 2021-11-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.