0 375

Cited 7 times in

Novel C-arm based planning spine surgery robot proved in a porcine model and quantitative accuracy assessment methodology

Authors
 Hyung Cheol Kim  ;  Hyeongseok Jeon  ;  Seong Bae An  ;  Hongho Kim  ;  Sungteac Hwang  ;  Yongyeob Cha  ;  Seohyun Moon  ;  Dong Ah Shin  ;  Yoon Ha  ;  Keung Nyun Kim  ;  Do Heum Yoon  ;  Seong Yi 
Citation
 INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, Vol.17(2) : e2182, 2021-04 
Journal Title
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY
ISSN
 1478-5951 
Issue Date
2021-04
MeSH
Animals ; Lumbar Vertebrae ; Pedicle Screws* ; Robotic Surgical Procedures* ; Spinal Fusion* ; Spine / diagnostic imaging ; Spine / surgery ; Swine ; Tomography, X-Ray Computed
Keywords
C-arm ; minimally invasive ; navigation ; pedicle screw ; robotics ; spinal surgery
Abstract
Background: We assessed pedicle screw accuracy utilizing a novel navigation-based spine surgery robotic system by comparing planned pathways with placed pathways in a porcine model.

Methods: We placed three mini screws per vertebra for accuracy evaluation and used a reference frame for registration in four pigs (46 screws in 23 vertebrae). We planned screw paths and performed screw insertion under robot guidance. Using C-arm and CT images, we evaluated accuracy by comparing the 3D distance of the placed screw head/tip from the planned screw head/tip and 3D angular offset.

Results: Mean registration deviation between the preoperative 3D space (C-arm) and postoperative CT scans was 0.475 ± 0.119 mm. The average offset from preoperative plan to final placement was 4.8 ± 2.0 mm from the head (tail), 5.3 ± 2.3 mm from the tip and 3.9 ± 2.4 degrees of angulation.

Conclusions: Our spine surgery robot showed good accuracy in executing an intended planned trajectory and screw path. This faster and more accurate robotic system will be applied in future studies, first in cadavers and subsequently in the clinical field.
Full Text
https://onlinelibrary.wiley.com/doi/10.1002/rcs.2182
DOI
10.1002/rcs.2182
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Keung Nyun(김긍년)
Kim, Hyung Cheol(김형철)
Shin, Dong Ah(신동아) ORCID logo https://orcid.org/0000-0002-5225-4083
An, Seong Bae(안성배)
Yoon, Do Heum(윤도흠) ORCID logo https://orcid.org/0000-0003-1452-5724
Yi, Seong(이성)
Jeon, Hyeong Seok(전형석)
Ha, Yoon(하윤)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/187769
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links