324 423

Cited 1 times in

Performance Evaluation of the KRYPTOR Compact PLUS Analyzer-Based B.R.A.H.M.S. CgA Ⅱ KRYPTOR Assay for Chromogranin A Measurement

DC Field Value Language
dc.contributor.author김신영-
dc.contributor.author박윤희-
dc.contributor.author이경아-
dc.date.accessioned2022-02-23T01:19:34Z-
dc.date.available2022-02-23T01:19:34Z-
dc.date.issued2021-12-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/187636-
dc.description.abstractNumerous immunoassays have been developed to measure the levels of chromogranin A (CgA), a useful biomarker for diagnosing and monitoring generally heterogeneous neuroendocrine tumors (NETs). Here, we evaluated the imprecision and linearity of three such assays: KRYPTOR (ThermoFisher Scientific), NEOLISA (EuroDiagnostica), and CgA-RIA (CisBio), using 123 samples for each assay. The correlation coefficients between the assays were 0.932 (CgA-RIA versus NEOLISA), 0.956 (KRYPTOR versus CgA-RIA), and 0.873 (NEOLISA versus KRYPTOR). KRYPTOR showed good precision, with percent coefficients of variation less than 5% for low and high concentration quality controls. Linearity was maintained over a wide concentration range. Comparison of CgA levels from three disease entities (NETs, non-NET pancreatic tumors, and prostate cancer) and healthy controls showed that patients with NETs had significantly higher CgA levels (n = 57, mean: 1.82 ± 0.43 log ng/mL) than healthy individuals (n = 20, mean: 1.51 ± 0.23 log ng/mL; p = 0.018). No other significant differences between groups were observed. All three immunoassays showed strong correlations in measured CgA levels. Because KRYPTOR operation uses a fully automated random-access system and requires shorter incubation times and smaller sample volumes, the KRYPTOR assay may improve laboratory workflow while maintaining satisfactory analytical performance.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherMDPI AG-
dc.relation.isPartOfDIAGNOSTICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titlePerformance Evaluation of the KRYPTOR Compact PLUS Analyzer-Based B.R.A.H.M.S. CgA Ⅱ KRYPTOR Assay for Chromogranin A Measurement-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorYu Jeong Choi-
dc.contributor.googleauthorJuhye Roh-
dc.contributor.googleauthorSinyoung Kim-
dc.contributor.googleauthorKyung-A Lee-
dc.contributor.googleauthorYounhee Park-
dc.identifier.doi10.3390/diagnostics11122400-
dc.contributor.localIdA00675-
dc.contributor.localIdA01606-
dc.contributor.localIdA02647-
dc.relation.journalcodeJ03798-
dc.identifier.eissn2075-4418-
dc.identifier.pmid34943638-
dc.subject.keywordbiomarker-
dc.subject.keywordchromogranin A-
dc.subject.keywordneuroendocrine tumor-
dc.contributor.alternativeNameKim, Sin Young-
dc.contributor.affiliatedAuthor김신영-
dc.contributor.affiliatedAuthor박윤희-
dc.contributor.affiliatedAuthor이경아-
dc.citation.volume11-
dc.citation.number12-
dc.citation.startPage2400-
dc.identifier.bibliographicCitationDIAGNOSTICS, Vol.11(12) : 2400, 2021-12-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.