280 443

Cited 0 times in

Evaluation of Dimensional Changes during Postcuring of a Three-Dimensionally Printed Denture Base According to the Curing Time and the Time of Removal of the Support Structure: An In Vitro Study

DC Field Value Language
dc.contributor.author김종은-
dc.contributor.author심준성-
dc.date.accessioned2021-12-28T17:30:48Z-
dc.date.available2021-12-28T17:30:48Z-
dc.date.issued2021-10-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/187135-
dc.description.abstractThis study attempted to determine the dimensional stability of maxillary and mandibular edentulous denture bases constructed using three-dimensional (3D) printing systems based on stereolithography and digital light processing according to the postcuring treatment time and the removal time of the support structure. Three-dimensional printing of the designed denture base file was performed using two types of 3D printing photocurable resin (standard gray resin (Formlabs) (Somerville, MA, USA) and MAZIC D resin (Vericom) (Anyang, Korea)) and their compatible 3D printers (Form3 (Formlabs) and Phrozen Shuffle (Phrozen) (Hsinchu City, Taiwan)). Different postcuring times (no postcuring, and 15, 30, 45, and 60 min) and times of removal of the support structure were set for each group. Data relating to the denture bases in all groups were obtained using 3D scanning with a tabletop scanner after postcuring. All acquired data were exported to 3D analysis software, and the dimensional changes during postcuring of the denture base were analyzed using RMSE (root-mean-square error) values. It could be confirmed that the dimensional changes increased with postcuring time, and the accuracy was higher in the maxilla than in the mandible. The accuracy was highest for the group in which the postcuring process was performed while the support structure was present.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherMDPI AG-
dc.relation.isPartOfAPPLIED SCIENCES-BASEL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEvaluation of Dimensional Changes during Postcuring of a Three-Dimensionally Printed Denture Base According to the Curing Time and the Time of Removal of the Support Structure: An In Vitro Study-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학교실)-
dc.contributor.googleauthorRe-Mee Doh-
dc.contributor.googleauthorJong-Eun Kim-
dc.contributor.googleauthorNa-Eun Nam-
dc.contributor.googleauthorSeung-Ho Shin-
dc.contributor.googleauthorJung-Hwa Lim-
dc.contributor.googleauthorJune-Sung Shim-
dc.identifier.doi10.3390/app112110000-
dc.contributor.localIdA00927-
dc.contributor.localIdA02211-
dc.relation.journalcodeJ03706-
dc.identifier.eissn2076-3417-
dc.subject.keyword3D printing-
dc.subject.keyworddimensional stability-
dc.subject.keywordsupport structure-
dc.subject.keywordpostcuring-
dc.contributor.alternativeNameKim, Jong Eun-
dc.contributor.affiliatedAuthor김종은-
dc.contributor.affiliatedAuthor심준성-
dc.citation.volume11-
dc.citation.number21-
dc.citation.startPage10000-
dc.identifier.bibliographicCitationAPPLIED SCIENCES-BASEL, Vol.11(21) : 10000, 2021-10-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.