222 387

Cited 0 times in

임상적 중요 농도에서의 동등성 평가를 위한 세 가지 칼시토닌 자동 면역검사의 비교

DC Field Value Language
dc.contributor.author이상국-
dc.contributor.author조용근-
dc.date.accessioned2021-12-28T17:08:26Z-
dc.date.available2021-12-28T17:08:26Z-
dc.date.issued2021-10-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/186955-
dc.description.abstractBackground: To date, only a few studies have focused on the standardization of the calcitonin assay, despite the fact that a lack of standardization of assays can lead to discrepancy in results. Here, we analyzed the concordance in serum calcitonin test results using three different assays. Methods: The serum calcitonin levels in 104 residual specimens collected between January and February 2020 were measured using three different systems. The Spearman’s rank correlation coefficients and the slopes and y-intercepts were assessed to derive all possible pairs of analyzers. The agreement of classification according to a clinically relevant cut-off was also evaluated using Cohen’s kappa coefficient. Results: The correlation coefficients for Cobas e801 versus LIAISON, Atellica IM-1600 versus LIAISON, and Cobas e801 versus Atellica IM-1600 were 0.77, 0.63, and 0.95, respectively. The kappa agreement of classification at a cut-off of 10 pg/mL was 0.81, 0.81, and 0.91, respectively. However, after excluding the data points for concentrations >20 pg/mL, the correlation coefficients decreased to 0.39, 0.22, and 0.90, respectively. Conclusions: Despite acceptable correlations for the full analytical measuring range, we observed limited correlations at low concentrations, especially around the clinical decision threshold. Therefore, continuous joint efforts by all stakeholders are essential for standardizing calcitonin assays.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisherKorean Society for Laboratory Medicine-
dc.relation.isPartOfLaboratory Medicine Online-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title임상적 중요 농도에서의 동등성 평가를 위한 세 가지 칼시토닌 자동 면역검사의 비교-
dc.title.alternativeComparison of Three Automated Calcitonin Immunoassays for Evaluating the Equivalence Near the Clinical Decision Point-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthor송준협-
dc.contributor.googleauthor조용근-
dc.contributor.googleauthor이상국-
dc.identifier.doi10.47429/lmo.2021.11.4.235-
dc.contributor.localIdA02810-
dc.contributor.localIdA03864-
dc.relation.journalcodeJ02151-
dc.identifier.eissn2093-6338-
dc.subject.keywordCalcitonin-
dc.subject.keywordStandardization-
dc.subject.keywordMethod comparison-
dc.subject.keywordImmunoassay-
dc.contributor.alternativeNameLee, Sang Guk-
dc.contributor.affiliatedAuthor이상국-
dc.contributor.affiliatedAuthor조용근-
dc.citation.volume11-
dc.citation.number4-
dc.citation.startPage235-
dc.citation.endPage244-
dc.identifier.bibliographicCitationLaboratory Medicine Online, Vol.11(4) : 235-244, 2021-10-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.