241 282

Cited 0 times in

Computational Study of Hemodynamic Changes Induced by Overlapping and Compacting of Stents and Flow Diverter in Cerebral Aneurysms

DC Field Value Language
dc.contributor.author김용배-
dc.date.accessioned2021-12-28T17:02:19Z-
dc.date.available2021-12-28T17:02:19Z-
dc.date.issued2021-08-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/186904-
dc.description.abstractPurpose: The flow diversion effect of an intracranial stent is closely related to its metal coverage rate (MCR). In this study, the flow diversion effects of Enterprise and low-profile visualized intraluminal support (LVIS) stents are compared with those of a Pipeline flow diverter, focusing on the MCR change. Moreover, the changes in the flow diversion effect caused by the additional manipulations of overlapping and compaction are verified using computational fluid dynamics (CFD) analysis. Methods: CFD analysis was performed using virtually generated stents mounted in an idealized aneurysm model. First, the flow diversion effects of single Enterprise, LVIS, and Pipeline devices were analyzed. The Enterprise and LVIS were sequentially overlapped and compared with a Pipeline, to evaluate the effect of stent overlapping. The effect of compacting a stent was evaluated by comparing the flow diversion effects of a single and two compacted LVIS with those of two overlapped, uncompacted LVIS and uncompacted and compacted Pipeline. Quantitative analysis was performed to evaluate the hemodynamic parameters of energy loss, average velocity, and inflow rate. Results: Statistically significant correlations were observed between the reduction rates of the hemodynamic parameters and MCR. The single LVIS without compaction induced a reduction in all the hemodynamic parameters comparable to those of the three overlapped Enterprise. Moreover, the two overlapped, uncompacted LVIS showed a flow diversion effect as large as that induced by the single uncompacted Pipeline. Compacted stents induced a better flow diversion effect than uncompacted stents. The single compacted LVIS induced a flow diversion effect similar to that induced by the two uncompacted LVIS or single uncompacted Pipeline. Conclusions: The MCR of a stent correlates with its flow diversion effect. Overlapping and compaction can increase the MCR of an intracranial stent and achieve a flow diversion effect as large as that observed with a flow diverter.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherFrontiers Research Foundation-
dc.relation.isPartOfFRONTIERS IN NEUROLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleComputational Study of Hemodynamic Changes Induced by Overlapping and Compacting of Stents and Flow Diverter in Cerebral Aneurysms-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Neurosurgery (신경외과학교실)-
dc.contributor.googleauthorSunghan Kim-
dc.contributor.googleauthorHyeondong Yang-
dc.contributor.googleauthorIneui Hong-
dc.contributor.googleauthorJe Hoon Oh-
dc.contributor.googleauthorYong Bae Kim-
dc.identifier.doi10.3389/fneur.2021.705841-
dc.contributor.localIdA00743-
dc.relation.journalcodeJ02996-
dc.identifier.eissn1664-2295-
dc.identifier.pmid34408723-
dc.subject.keywordcompaction-
dc.subject.keywordcomputational fluid dynamics-
dc.subject.keywordflow diversion effect-
dc.subject.keywordflow diverter-
dc.subject.keywordmetal coverage rate-
dc.subject.keywordoverlapping-
dc.subject.keywordstent-
dc.contributor.alternativeNameKim, Yong Bae-
dc.contributor.affiliatedAuthor김용배-
dc.citation.volume12-
dc.citation.startPage705841-
dc.identifier.bibliographicCitationFRONTIERS IN NEUROLOGY, Vol.12 : 705841, 2021-08-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.