97 242

Cited 0 times in

피부 결손 환자에서 탄성을 이용한 신연 봉합술

DC Field Value Language
dc.contributor.author양규현-
dc.date.accessioned2021-12-27T17:30:54Z-
dc.date.available2021-12-27T17:30:54Z-
dc.date.issued1995-04-
dc.identifier.issn1226-2102-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/186704-
dc.description.abstractSkin defects unable to close by primary intention have caused many difficulties. Complex surgical interventions such as repetitive debridements, skin graft, or flap have been performed as therapeutic methods. Recently, new techniques for the skin closure based on the stretching property, elasticity or stress relaxation, have been introduced. This biomechanical property exhibits that the force required to keep the skin at a stretched length decreases over time. As the skin is stretching, the convoluted collagen fibers in dermis are straighten and become a line in the direction of stretching force. Fifteen cases of skin defects associated with fracture were closed by a new dynamic closing method at Department of Orthopaedic Surgery, Yonsei University College of Medicine. Two spinal needles were inserted into dermis along the wound margins on each side in order to distribute the even tension. The wound margins were approximated by suture wires engaged with the needles. We have experienced successful results using new stretch closing method in fracture with skin defect. It is confirmed that this method is rapid, simple, cost-effective, cosmetic, and safe way to close the skin defect and shortens hospital stay.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한정형외과학회-
dc.relation.isPartOfJournal of the Korean Orthopaedic Association(대한정형외과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title피부 결손 환자에서 탄성을 이용한 신연 봉합술-
dc.title.alternativeDynamic Closing Method Using Elasticity for Skin Defect-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Orthopedic Surgery (정형외과학교실)-
dc.contributor.googleauthor양규현-
dc.contributor.googleauthor한대용-
dc.contributor.googleauthor한수봉-
dc.contributor.googleauthor김현정-
dc.contributor.localIdA02282-
dc.relation.journalcodeJ01839-
dc.identifier.eissn2005-8918-
dc.contributor.alternativeNameYang, Kyu Hyun-
dc.contributor.affiliatedAuthor양규현-
dc.citation.volume30-
dc.citation.number2-
dc.citation.startPage403-
dc.citation.endPage409-
dc.identifier.bibliographicCitationJournal of the Korean Orthopaedic Association (대한정형외과학회지), Vol.30(2) : 403-409, 1995-04-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.