148 300

Cited 0 times in

시간 경과에 따른 부가중합형 실리콘 인상재의 수소 발생

DC Field Value Language
dc.contributor.author김경남-
dc.contributor.author이근우-
dc.date.accessioned2021-12-27T17:13:34Z-
dc.date.available2021-12-27T17:13:34Z-
dc.date.issued1995-01-
dc.identifier.issn1225-1631-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/186481-
dc.description.abstractClinical reports have indicated that there occurs many bubbles on the surface of the gypsum model because of the hydrogen release from the addition silicon impression materials. Recently the products containing hydrogen absorber have been being developed but not perfect yet. In this study, 4 type III dental stones(New Fujirock ; G.C., New Plastone : G.C., MG dental stone ; Maruishi, Suprastone : Kerr) was poured into the impression of detail-reproducing test block taken using addition-type silicones(Correct VPS ; J/P, Exafine ; G.C., Express ; 3M, Extrude; Kerr, Provil; Bayer, Reprosil; Dentsply) with the intervals of 0, 15, 30, 45, 60, 90, and 120 minutes. Gypsum model was removed from the impressions and the number of bubbles on the surface of casts was counted after 30 min. Ordinal numbers were given to the ranges of the number of bubbles like this, Score 0, 0, 1; 1~10, 2; 11~30, 3; 31~60. 4;61~100, 5; 101~200, 6; 201~40, 7; 401 or more There was no bubble in Correct VPS impression poured immediately in MG dental stone and Extrude impression poured immediately in New Fujirock, New Plastone, and MG dental stone. Significant bubbles were appeared in Provil until 15 minutes (Score 1~3), Reprosil until 30 minutes(Score 1~2), and Express until 45 minutes(Score 1~2) in all gypsum models(p<0.05). Express impression poured in Suprastone(Score 2) and New Platone(Score 4) had bubbles until 120 minutes(p<0.05). On the basis of this study it can be concluded that not only hydrogen release but also compatibility with gypsum should be considered when using addition silicones.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한치과기재학회-
dc.relation.isPartOfJournal of the Korean Research Society for Dental Materials(대한치과기재학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title시간 경과에 따른 부가중합형 실리콘 인상재의 수소 발생-
dc.title.alternativeRELEASE OF HYDROGEN FROM THE ADDITION SILICONE IMPRESSION AMTERIALS AS A FUNCTION OF TIME-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실)-
dc.contributor.googleauthor고영무-
dc.contributor.googleauthor김경남-
dc.contributor.googleauthor이근우-
dc.contributor.localIdA00292-
dc.contributor.localIdA02688-
dc.relation.journalcodeJ01846-
dc.contributor.alternativeNameKim, Kyoung Nam-
dc.contributor.affiliatedAuthor김경남-
dc.contributor.affiliatedAuthor이근우-
dc.citation.volume22-
dc.citation.number1-
dc.citation.startPage47-
dc.citation.endPage55-
dc.identifier.bibliographicCitationJournal of the Korean Research Society for Dental Materials (대한치과기재학회지), Vol.22(1) : 47-55, 1995-01-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.