115 401

Cited 0 times in

Cited 0 times in

폐쇄회로 장치에 의한 TDI - 흡입 기관지유발시험

Other Titles
 Toluene diisocyanate inhalation bronchial callenge test with a closed-circuit device 
Authors
 김철우  ;  최영화  ;  강석민  ;  박중원  ;  홍천수 
Citation
 Allergy (알레르기), Vol.15(4) : 598-610, 1995-12 
Journal Title
Allergy(알레르기)
ISSN
 1015-6372 
Issue Date
1995-12
Abstract
Occupational asthma is the most common respiratory disease related to the working environmerlts. Isocyanates, especially toluene diisocyanate(TDI), are currently the most common cause of occupational asthma both in Korea and in other industrialized countries. The diagnosis of TDI-induced asthma can be confirmed by inhalation challenge test, usually performed in small challenge room. But there are several pitfalls in this method. Inhsled TDI concentrations can not be checked accurately and may not remain stable throught the procedure. And there are some risk of sensitization to an nonsensitized medical personnel participated in the test. To overcome these problems we simply modified previously reported closed-circuit methodology and made a simple closed -circuit device for challenge test, and then performed inhalation challenge test to 7 bronchial asthmatics who were suspected TDI-induced asthma by personal and occupa- tional history. Of the 7 cases, we designed challenge test to inhsle 20ppb concentrations of TDI for 20 minutes in 5 cases. During inhalation we checked inhaled TDI concentration at 1 minute interval, and the concentrations were frequently exceeded the recommended threshold limit value ceiling(TLVC) of 20ppb in all 5 cases and severe bronchial reactions were noted. Thus 6th case was recommened to inhale subirritant concentration(mean 12.6 + 4.2ppb) of TDI not exceeding the TLVC. After inhalation for 11 minutes, he complained of dyspnea and wheezing, and atypical prolonged immediate reaction was noted on serial pulmonary function monitoring. The last 7th case inhaled compressed air only as placebo on first day and no significant change of FEV20 was seen. On second day he inhaled 4.2+ 1.8ppb concentrstion of TDI for 20 minutes, but no immediate reaction was developed. Thus he inhaled 10.4+2.7ppb concentration of TDI again, and on serial pulmonary function monitoring, isolated late asthmatic reaction was noted. So we concluded that inhalation challenge test with simply modified closed-circuit device was a clinically useful and reliable methodology fot the diagnosis of TDI-induced asthma.
Files in This Item:
T199501123.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Park, Jung Won(박중원) ORCID logo https://orcid.org/0000-0003-0249-8749
Hong, Chein Soo(홍천수)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/186293
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links