0 231

Cited 0 times in

False localization of rupture by computed tomography in bilateral internal carotid artery aneurysms

DC Field Value Language
dc.contributor.author주진양-
dc.date.accessioned2021-12-27T16:49:39Z-
dc.date.available2021-12-27T16:49:39Z-
dc.date.issued1995-05-
dc.identifier.issn0090-3019-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/186174-
dc.description.abstractBACKGROUND: Focal clot on computed tomographic (CT) scan is one of the most reliable clues in determining the site of rupture in patients with multiple intracranial aneurysms. However, unusual presentation of clot may cause false localization of the ruptured aneurysm in bilateral aneurysms, particularly when they are located near the midline. METHODS: We describe two cases of bilateral internal carotid artery (ICA) aneurysms presenting contralateral distribution of clot on CT scan. RESULTS: Misjudgment of rupture site by the CT scan resulted in clipping of the wrong aneurysm in one patient. Disastrous rebleeding occurred before the second operation for the ruptured one. In the other patient, the rupture site was assumed correctly despite contralateral situation of clot on CT, and both aneurysms were treated in one operative session. CONCLUSIONS: Adhesion and obliteration of the subarachnoid cisterns from previous hemorrhage will deviate the direction of hemorrhage and present contralateral clot on CT scan in bilateral aneurysms located near the midline as ICA aneurysms. Medial direction of rupture may obscure accurate localization of rupture side in such aneurysms.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherElsevier Science Publishing-
dc.relation.isPartOfSURGICAL NEUROLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHCarotid Artery Diseases / diagnostic imaging*-
dc.subject.MESHCarotid Artery, Internal / diagnostic imaging-
dc.subject.MESHCerebral Angiography-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHIntracranial Aneurysm / diagnostic imaging*-
dc.subject.MESHIntracranial Aneurysm / physiopathology-
dc.subject.MESHMiddle Aged-
dc.subject.MESHRupture / physiopathology-
dc.subject.MESHTomography, X-Ray Computed-
dc.titleFalse localization of rupture by computed tomography in bilateral internal carotid artery aneurysms-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Neurosurgery (신경외과학교실)-
dc.contributor.googleauthorKyu-Chang Lee-
dc.contributor.googleauthorJin-Yang Joo-
dc.contributor.googleauthorKyu-Sung Lee-
dc.identifier.doi10.1016/0090-3019(95)00409-2-
dc.contributor.localIdA03959-
dc.relation.journalcodeJ02708-
dc.identifier.eissn1879-3339-
dc.identifier.pmid8629243-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/0090301995004092-
dc.contributor.alternativeNameJoo, Jin Yang-
dc.contributor.affiliatedAuthor주진양-
dc.citation.volume45-
dc.citation.number5-
dc.citation.startPage435-
dc.citation.endPage441-
dc.identifier.bibliographicCitationSURGICAL NEUROLOGY, Vol.45(5) : 435-441, 1995-05-