245 402

Cited 2 times in

Development and Performance Evaluation of Wearable Respiratory Self-Training System Using Patch Type Magnetic Sensor

DC Field Value Language
dc.contributor.author김동욱-
dc.contributor.author김지훈-
dc.contributor.author김진성-
dc.contributor.author김호진-
dc.contributor.author홍채선-
dc.date.accessioned2021-09-29T02:02:41Z-
dc.date.available2021-09-29T02:02:41Z-
dc.date.issued2021-08-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/184682-
dc.description.abstractPurpose: Respiratory training system that can be used by patients themselves was developed with a micro-electro-mechanical-system (MEMS)-based patch-type magnetic sensor. We conducted a basic function test and clinical usability evaluation to determine the system’s clinical applicability. Methods: The system is designed with a sensor attached to the patient’s chest and a magnet on the back to monitor the patient’s respiration by measuring changes in magnetic intensity related to respiratory movements of the thoracic surface. The system comprises a MEMS-based patch-type magnetic sensor capable of wireless communication and being applied to measurement magnets and mobile applications. System performance was evaluated by the level of systemic noise, the precision of the sensor in various breathing patterns, how measurement signals change for varying distances, or the presence or absence of material between the sensor and the magnet. Various breathing patterns were created using the QUASAR respiratory motion phantom; the data obtained were analyzed using the fitting and peak value analysis methods. Results: The sensor had a noise ratio of <0.54% of the signal; the average errors in signal amplitude and period for breathing patterns were 78.87 um and 72 ms, respectively. The signal could be measured consistently when the sensor–magnet distance was 10–25 cm. The signal difference was 1.89% for the presence or absence of a material, indicating that its influence on the measurement signal is relatively small. Conclusion: The potential of our MEMS-based patch-type wearable respiratory self-training system was confirmed via basic function tests and clinical usability evaluations. We believe that the training system could provide thorough respiratory training for patients after a clinical trial with actual patients confirming its clinical efficacy and usability.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherFrontiers Research Foundation-
dc.relation.isPartOfFRONTIERS IN ONCOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleDevelopment and Performance Evaluation of Wearable Respiratory Self-Training System Using Patch Type Magnetic Sensor-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorHyo Kyeong Kang-
dc.contributor.googleauthorHojin Kim-
dc.contributor.googleauthorChae-Seon Hong-
dc.contributor.googleauthorJihun Kim-
dc.contributor.googleauthorJin Sung Kim-
dc.contributor.googleauthorDong Wook Kim-
dc.identifier.doi10.3389/fonc.2021.680147-
dc.contributor.localIdA05710-
dc.contributor.localIdA05823-
dc.contributor.localIdA04548-
dc.contributor.localIdA05970-
dc.contributor.localIdA05846-
dc.relation.journalcodeJ03512-
dc.identifier.eissn2234-943X-
dc.subject.keywordradiation therapy-
dc.subject.keywordrespiratory monitoring-
dc.subject.keywordrespiratory self-training-
dc.subject.keywordpatch-type magnetic sensor-
dc.subject.keywordmicro electro-mechanical-system (MEMS)-
dc.contributor.alternativeNameKim, Dong Wook-
dc.contributor.affiliatedAuthor김동욱-
dc.contributor.affiliatedAuthor김지훈-
dc.contributor.affiliatedAuthor김진성-
dc.contributor.affiliatedAuthor김호진-
dc.contributor.affiliatedAuthor홍채선-
dc.citation.volume11-
dc.citation.startPage680147-
dc.identifier.bibliographicCitationFRONTIERS IN ONCOLOGY, Vol.11 : 680147, 2021-08-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.