209 366

Cited 13 times in

Ability of Carotid Corrected Flow Time to Predict Fluid Responsiveness in Patients Mechanically Ventilated Using Low Tidal Volume after Surgery

DC Field Value Language
dc.contributor.author김도형-
dc.contributor.author김정민-
dc.contributor.author나성원-
dc.contributor.author정승호-
dc.date.accessioned2021-09-29T00:59:14Z-
dc.date.available2021-09-29T00:59:14Z-
dc.date.issued2021-06-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/184134-
dc.description.abstractPredicting fluid responsiveness in patients under mechanical ventilation with low tidal volume (VT) is challenging. This study evaluated the ability of carotid corrected flow time (FTc) assessed by ultrasound for predicting the fluid responsiveness during low VT ventilation. Patients under postoperative mechanical ventilation and clinically diagnosed with hypovolemia were enrolled. Carotid FTc and pulse pressure variation (PPV) were measured at VT of 6 and 10 mL/kg predicted body weight (PBW). FTc was calculated using both Bazett's (FTcB) and Wodey's (FTcW) formulas. Fluid responsiveness was defined as a ≥15% increase in the stroke volume index assessed by FloTrac/Vigileo monitor after administration of 8 mL/kg of balanced crystalloid. Among 36 patients, 16 (44.4%) were fluid responders. The areas under the receiver operating characteristic curves (AUROCs) for the FTcB at VT of 6 and 10 mL/kg PBW were 0.897 (95% confidence interval [95% CI]: 0.750-0.973) and 0.895 (95% CI: 0.748-0.972), respectively. The AUROCs for the FTcW at VT of 6 and 10 mL/kg PBW were 0.875 (95% CI: 0.722-0.961) and 0.891 (95% CI: 0.744-0.970), respectively. However, PPV at VT of 6 mL/kg PBW (AUROC: 0.714, 95% CI: 0.539-0.852) showed significantly lower accuracy than that of PPV at VT of 10 mL/kg PBW (AUROC: 0.867, 95% CI: 0.712-0.957; p = 0.034). Carotid FTc can predict fluid responsiveness better than PPV during low VT ventilation. However, further studies using automated continuous monitoring system are needed before its clinical use.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherMDPI AG-
dc.relation.isPartOfJOURNAL OF CLINICAL MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleAbility of Carotid Corrected Flow Time to Predict Fluid Responsiveness in Patients Mechanically Ventilated Using Low Tidal Volume after Surgery-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology and Pain Medicine (마취통증의학교실)-
dc.contributor.googleauthorSeungho Jung-
dc.contributor.googleauthorJeongmin Kim-
dc.contributor.googleauthorSungwon Na-
dc.contributor.googleauthorWon Seok Nam-
dc.contributor.googleauthorDo-Hyeong Kim-
dc.identifier.doi10.3390/jcm10122676-
dc.contributor.localIdA00390-
dc.contributor.localIdA00884-
dc.contributor.localIdA01232-
dc.contributor.localIdA05811-
dc.relation.journalcodeJ03556-
dc.identifier.eissn2077-0383-
dc.identifier.pmid34204523-
dc.subject.keywordDoppler ultrasound-
dc.subject.keywordcarotid artery-
dc.subject.keywordflow time-
dc.subject.keywordfluid therapy-
dc.subject.keywordtidal volume-
dc.contributor.alternativeNameKim, Do Hyeong-
dc.contributor.affiliatedAuthor김도형-
dc.contributor.affiliatedAuthor김정민-
dc.contributor.affiliatedAuthor나성원-
dc.contributor.affiliatedAuthor정승호-
dc.citation.volume10-
dc.citation.number12-
dc.citation.startPage2676-
dc.identifier.bibliographicCitationJOURNAL OF CLINICAL MEDICINE, Vol.10(12) : 2676, 2021-06-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.