High-performance portable graphene field-effect transistor device for detecting Gram-positive and -negative bacteria

DC Field Value Language
dc.contributor.author용동은-
dc.date.accessioned2021-09-29T00:33:05Z-
dc.date.available2021-09-29T00:33:05Z-
dc.date.issued2020-11-
dc.identifier.issn0956-5663-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/183908-
dc.description.abstractCurrent techniques for Gram-typing and for diagnosing a pathogen at the early infection stage rely on Gram stains, cultures, Enzyme linked immunosorbent assay (ELISA), polymerase chain reaction (PCR), and gene microarrays, which are labor-intensive and time-consuming approaches. In addition, a delayed or imprecise diagnosis of clinical pathogenic bacteria leads to a life-threatening emergency or overuse of antibiotics and a high-rate occurrence of antimicrobial-resistance microbes. Herein, we report high-performance antibiotics (as bioprobes) conjugated graphene micropattern field-effect transistors (ABX-GMFETs) to facilitate on-site Gram-typing and help in the detection of the presence or absence of Gram-negative and -positive bacteria in the samples. The ABX-GMFET platform, which consists of recognition probes and GM transistors conjugated with novel interfacing chemical compounds, was integrated into the microfluidics to minimize the required human intervention and facilitate automation. The mechanism of binding of ABX-GMFET was based on a charge or chemical moiety interaction between the bioprobes and target bacteria. Subsequently, ABX-GMFETs exhibited unprecedented high sensitivity with a limit of detection (LOD) of 100 CFU/mL (1-9 CFU/mL), real-time target specificity.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherElsevier Advanced Technology-
dc.relation.isPartOfBIOSENSORS & BIOELECTRONICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHBacteria-
dc.subject.MESHBiosensing Techniques*-
dc.subject.MESHGraphite*-
dc.subject.MESHHumans-
dc.subject.MESHLimit of Detection-
dc.subject.MESHPolymerase Chain Reaction-
dc.titleHigh-performance portable graphene field-effect transistor device for detecting Gram-positive and -negative bacteria-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorKyung Ho Kim-
dc.contributor.googleauthorSeon Joo Park-
dc.contributor.googleauthorChul Soon Park-
dc.contributor.googleauthorSung Eun Seo-
dc.contributor.googleauthorJiyeon Lee-
dc.contributor.googleauthorJinyeong Kim-
dc.contributor.googleauthorSeung Hwan Lee-
dc.contributor.googleauthorSoohyun Lee-
dc.contributor.googleauthorJun-Seob Kim-
dc.contributor.googleauthorChoong-Min Ryu-
dc.contributor.googleauthorDongeun Yong-
dc.contributor.googleauthorHyeonseok Yoon-
dc.contributor.googleauthorHyun Seok Song-
dc.contributor.googleauthorSang Hun Lee-
dc.contributor.googleauthorOh Seok Kwon-
dc.identifier.doi10.1016/j.bios.2020.112514-
dc.contributor.localIdA02423-
dc.relation.journalcodeJ00330-
dc.identifier.eissn1873-4235-
dc.identifier.pmid32866713-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0956566320305066-
dc.subject.keywordBioprobes-
dc.subject.keywordGraphene field-effect transistor-
dc.subject.keywordInterfacing chemistry-
dc.subject.keywordMicrofluidics-
dc.subject.keywordPortable biosensor-
dc.subject.keywordReal-time monitoring-
dc.contributor.alternativeNameYong, Dong Eun-
dc.contributor.affiliatedAuthor용동은-
dc.citation.volume167-
dc.citation.startPage112514-
dc.identifier.bibliographicCitationBIOSENSORS & BIOELECTRONICS, Vol.167 : 112514, 2020-11-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.