High-performance portable graphene field-effect transistor device for detecting Gram-positive and -negative bacteria

DC Field Value Language
dc.contributor.authorKim, Kyung Ho-
dc.contributor.authorPark, Seon Joo-
dc.contributor.authorPark, Chul Soon-
dc.contributor.authorSeo, Sung Eun-
dc.contributor.authorLee, Jiyeon-
dc.contributor.authorKim, Jinyeong-
dc.contributor.authorLee, Seung Hwan-
dc.contributor.authorLee, Soohyun-
dc.contributor.authorKim, Jun-Seob-
dc.contributor.authorRyu, Choong-Min-
dc.contributor.authorYong, Dong Eun-
dc.contributor.authorYoon, Hyeonseok-
dc.contributor.authorSong, Hyun Seok-
dc.contributor.authorLee, Sang Hun-
dc.contributor.authorKwon, Oh Seok-
dc.date.accessioned2021-09-29T00:33:05Z-
dc.date.available2021-09-29T00:33:05Z-
dc.date.created2022-01-19-
dc.date.issued2020-11-
dc.identifier.issn0956-5663-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/183908-
dc.description.abstractCurrent techniques for Gram-typing and for diagnosing a pathogen at the early infection stage rely on Gram stains, cultures, Enzyme linked immunosorbent assay (ELISA), polymerase chain reaction (PCR), and gene microarrays, which are labor-intensive and time-consuming approaches. In addition, a delayed or imprecise diagnosis of clinical pathogenic bacteria leads to a life-threatening emergency or overuse of antibiotics and a high-rate occurrence of antimicrobial-resistance microbes. Herein, we report high-performance antibiotics (as bioprobes) conjugated graphene micropattern field-effect transistors (ABX-GMFETs) to facilitate on-site Gram-typing and help in the detection of the presence or absence of Gram-negative and -positive bacteria in the samples. The ABX-GMFET platform, which consists of recognition probes and GM transistors conjugated with novel interfacing chemical compounds, was integrated into the microfluidics to minimize the required human intervention and facilitate automation. The mechanism of binding of ABX-GMFET was based on a charge or chemical moiety interaction between the bioprobes and target bacteria. Subsequently, ABX-GMFETs exhibited unprecedented high sensitivity with a limit of detection (LOD) of 10(0) CFU/mL (1-9 CFU/mL), real-time target specificity.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherElsevier Advanced Technology-
dc.relation.isPartOfBiosensors and Bioelectronics-
dc.relation.isPartOfBIOSENSORS & BIOELECTRONICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleHigh-performance portable graphene field-effect transistor device for detecting Gram-positive and -negative bacteria-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorKim, Kyung Ho-
dc.contributor.googleauthorPark, Seon Joo-
dc.contributor.googleauthorPark, Chul Soon-
dc.contributor.googleauthorSeo, Sung Eun-
dc.contributor.googleauthorLee, Jiyeon-
dc.contributor.googleauthorKim, Jinyeong-
dc.contributor.googleauthorLee, Seung Hwan-
dc.contributor.googleauthorLee, Soohyun-
dc.contributor.googleauthorKim, Jun-Seob-
dc.contributor.googleauthorRyu, Choong-Min-
dc.contributor.googleauthorYong, Dong Eun-
dc.contributor.googleauthorYoon, Hyeonseok-
dc.contributor.googleauthorSong, Hyun Seok-
dc.contributor.googleauthorLee, Sang Hun-
dc.contributor.googleauthorKwon, Oh Seok-
dc.identifier.doi10.1016/j.bios.2020.112514-
dc.relation.journalcodeJ00330-
dc.identifier.eissn1873-4235-
dc.subject.keywordPortable biosensor-
dc.subject.keywordGraphene field-effect transistor-
dc.subject.keywordInterfacing chemistry-
dc.subject.keywordMicrofluidics-
dc.subject.keywordReal-time monitoring-
dc.subject.keywordBioprobes-
dc.contributor.alternativeNameYong, Dong Eun-
dc.contributor.affiliatedAuthorYong, Dong Eun-
dc.identifier.scopusid2-s2.0-85089889852-
dc.identifier.wosid000569861900001-
dc.citation.volume167-
dc.identifier.bibliographicCitationBiosensors and Bioelectronics, Vol.167, 2020-11-
dc.identifier.rimsid71922-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorPortable biosensor-
dc.subject.keywordAuthorGraphene field-effect transistor-
dc.subject.keywordAuthorInterfacing chemistry-
dc.subject.keywordAuthorMicrofluidics-
dc.subject.keywordAuthorReal-time monitoring-
dc.subject.keywordAuthorBioprobes-
dc.subject.keywordPlusESCHERICHIA-COLI-
dc.subject.keywordPlusSTAPHYLOCOCCUS-AUREUS-
dc.subject.keywordPlusSURFACE-CHARGE-
dc.subject.keywordPlusVANCOMYCIN-
dc.subject.keywordPlusLIMITATIONS-
dc.subject.keywordPlusHYDROGEL-
dc.subject.keywordPlusCARBON-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryBiophysics-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalResearchAreaBiophysics-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.identifier.articleno112514-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.