221 430

Cited 0 times in

Cited 0 times in

관동맥내 Flexible Coil(Gianturco-Roubin) 스텐트 삽입후 추적혈관 조영 소견

DC Field Value Language
dc.contributor.author심원흠-
dc.contributor.author이문형-
dc.contributor.author하종원-
dc.date.accessioned2021-09-28T07:52:13Z-
dc.date.available2021-09-28T07:52:13Z-
dc.date.issued1996-01-
dc.identifier.issn1738-5520-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/183239-
dc.description.abstractBackground: Intracoronary stent with various designs have been developed to treat dissections or acute closure after angioplasty. The efficacy of flexible coil stent as a bail-out device has been reported. However, the restenosis after stenting still remained as a main limitation like other devices. This study reports on the angiographic follow-up after successful intracoronary stenting with flexible coil stent. Method: From April 1993 through July 1994, coronary stenting was tried in 21 patients by a single operator for various indications(acute or threatened closure, suboptimal result after balloon angioplasty). The nineteen(95%) out of 20 patients in whom stent was successfully deployed underwent follow-up coronary angiography 7.6±3.0 months after coronary stenting. Result: Mean age was 54.7±11.3(33-73) years and 16 parients were men. Clinical diagnosis of patients were as follows : stable angina 7, unstable angina 6, old myocardial infarction with stable angina 6 and acute myocardial infarction in 1 patient, respectively. Stents were implanted at left anterior descending artery in 9, left circumflex artery in 5 and right coronary artery in 8. Ten out of 21 stents(47.6%) were found to be renarrowed more than 50% at follow-up coronary angiography. There was no significant difference in clinical and angiographic variables between restenosis group and no-restenosis group. Coronary artery bypass graft surgery was performed in 1 patient for the treatment of restenosis after stenting. Repeat PTCA was performed in 3 patients and remaining 5 patients were followed medically. Conclusion: Flexible coil(Gianturco-Roubin) coronary stent is a useful adjunct percutaneous intervention to prevent or minimize complicatioms associated with dissections. Despite favorable initial angiographic and clinical results, 47.6% of stents were found to be renarrowed significantly at follow-up coronary angiography. New techniques or more optimal characters of stents would be desired.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한심장학회-
dc.relation.isPartOfKOREAN CIRCULATION JOURNAL(순환기)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title관동맥내 Flexible Coil(Gianturco-Roubin) 스텐트 삽입후 추적혈관 조영 소견-
dc.title.alternativeAngiographic Follow-Up After Intracoronary Stenting with Flexible Coil(Gianturco-Roubin) Stent-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthor심원흠-
dc.contributor.googleauthor하종원-
dc.contributor.googleauthor임상욱-
dc.contributor.googleauthor권준-
dc.contributor.googleauthor이문형-
dc.identifier.doi10.4070/kcj.1996.26.1.29-
dc.contributor.localIdA02202-
dc.contributor.localIdA02766-
dc.contributor.localIdA04257-
dc.relation.journalcodeJ01953-
dc.identifier.eissn1738-5555-
dc.subject.keywordFlexible coil(Gianturco-Roubin) coronary stent-
dc.subject.keywordAngiographic follow-up-
dc.contributor.alternativeNameShim, Won Heum-
dc.contributor.affiliatedAuthor심원흠-
dc.contributor.affiliatedAuthor이문형-
dc.contributor.affiliatedAuthor하종원-
dc.citation.volume26-
dc.citation.number1-
dc.citation.startPage29-
dc.citation.endPage34-
dc.identifier.bibliographicCitationKorean Circulation Journal (순환기), Vol.26(1) : 29-34, 1996-01-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.