Cited 0 times in
Peri-anchor cyst formation after arthroscopic bankart repair: comparison between biocomposite suture anchor and all-suture anchor
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 천용민 | - |
dc.date.accessioned | 2021-05-21T16:56:16Z | - |
dc.date.available | 2021-05-21T16:56:16Z | - |
dc.date.issued | 2020-11 | - |
dc.identifier.issn | 1226-9344 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/182624 | - |
dc.description.abstract | Background The purpose of this study is to investigate clinical outcomes and radiological findings of cyst formation in the glenoid around suture anchors after arthroscopic Bankart repair with either biocomposite suture anchor or all-suture anchor in traumatic anterior shoulder instability. We hypothesized that there would be no significant difference in clinical and radiological outcomes between the two suture materials. Methods This retrospective study reviewed 162 patients (69 in group A, biocomposite anchor; 93 in group B, all-suture anchor) who underwent arthroscopic Bankart repair of traumatic recurrent anterior shoulder instability with less than 20% glenoid defect on preoperative en-face view three-dimensional computed tomography. Patient assignment was not randomized. Results At final follow-up, the mean subjective shoulder value, Rowe score, and University of California, Los Angeles shoulder score improved significantly in both groups. However, there were no significant differences in functional shoulder scores and recurrence rate (6%, 4/69 in group A; 5%, 5/93 in group B) between the two groups. On follow-up magnetic resonance arthrography/computed tomography arthrography, the incidence of peri-anchor cyst formation was 5.7% (4/69) in group A and 3.2% (3/93) in group B, which was not a significant difference. Conclusions Considering the low incidence of peri-anchor cyst formation in the glenoid after Bankart repair with one of two anchor systems and the lack of association with recurrence instability, biocomposite and all-suture anchors in Bankart repair yield satisfactory outcomes with no significant difference. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한견주관절학회 | - |
dc.relation.isPartOf | Journal of the Korean Shoulder and Elbow Society (대한견주관절학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Peri-anchor cyst formation after arthroscopic bankart repair: comparison between biocomposite suture anchor and all-suture anchor | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Orthopedic Surgery (정형외과학교실) | - |
dc.contributor.googleauthor | Seokhwan Jin | - |
dc.contributor.googleauthor | Yong-Min Chun | - |
dc.identifier.doi | 10.5397/cise.2020.00290 | - |
dc.contributor.localId | A04028 | - |
dc.relation.journalcode | J01848 | - |
dc.subject.keyword | Shoulder | - |
dc.subject.keyword | Joint instability | - |
dc.subject.keyword | Arthroscopic surgery | - |
dc.subject.keyword | Suture anchor | - |
dc.subject.keyword | Cyst | - |
dc.contributor.alternativeName | Chun, Yong Min | - |
dc.contributor.affiliatedAuthor | 천용민 | - |
dc.citation.volume | 23 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 178 | - |
dc.citation.endPage | 182 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Shoulder and Elbow Society (대한견주관절학회지), Vol.23(4) : 178-182, 2020-11 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.