331 433

Cited 5 times in

Patient-Specific Quality Assurance Using a 3D-Printed Chest Phantom for Intraoperative Radiotherapy in Breast Cancer

DC Field Value Language
dc.contributor.author김준원-
dc.contributor.author박광우-
dc.contributor.author이익재-
dc.contributor.author이호-
dc.contributor.author조연아-
dc.date.accessioned2021-04-29T17:20:55Z-
dc.date.available2021-04-29T17:20:55Z-
dc.date.issued2021-03-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/182298-
dc.description.abstractThis study aims to confirm the usefulness of patient-specific quality assurance (PSQA) using three-dimensional (3D)-printed phantoms in ensuring the stability of IORT and the precision of the treatment administered. In this study, five patient-specific chest phantoms were fabricated using a 3D printer such that they were dosimetrically equivalent to the chests of actual patients in terms of organ density and shape around the given target, where a spherical applicator was inserted for breast IORT treatment via the INTRABEAM™ system. Models of lungs and soft tissue were fabricated by applying infill ratios corresponding to the mean Hounsfield unit (HU) values calculated from CT scans of the patients. The two models were then assembled into one. A 3D-printed water-equivalent phantom was also fabricated to verify the vendor-provided depth dose curve. Pieces of an EBT3 film were inserted into the 3D-printed customized phantoms to measure the doses. A 10 Gy prescription dose based on the surface of the spherical applicator was delivered and measured through EBT3 films parallel and perpendicular to the axis of the beam. The shapes of the phantoms, CT values, and absorbed doses were compared between the expected and printed ones. The morphological agreement among the five patient-specific 3D chest phantoms was assessed. The mean differences in terms of HU between the patients and the phantoms was 2.2 HU for soft tissue and -26.2 HU for the lungs. The dose irradiated on the surface of the spherical applicator yielded a percent error of -2.16% ± 3.91% between the measured and prescribed doses. In a depth dose comparison using a 3D-printed water phantom, the uncertainty in the measurements based on the EBT3 film decreased as the depth increased beyond 5 mm, and a good agreement in terms of the absolute dose was noted between the EBT3 film and the vendor data. These results demonstrate the applicability of the 3D-printed chest phantom for PSQA in breast IORT. This enhanced precision offers new opportunities for advancements in IORT.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherFrontiers Research Foundation-
dc.relation.isPartOfFRONTIERS IN ONCOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titlePatient-Specific Quality Assurance Using a 3D-Printed Chest Phantom for Intraoperative Radiotherapy in Breast Cancer-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorYeonho Choi-
dc.contributor.googleauthorIk Jae Lee-
dc.contributor.googleauthorKwangwoo Park-
dc.contributor.googleauthorKyung Ran Park-
dc.contributor.googleauthorYeona Cho-
dc.contributor.googleauthorJun Won Kim-
dc.contributor.googleauthorHo Lee-
dc.identifier.doi10.3389/fonc.2021.629927-
dc.contributor.localIdA00958-
dc.contributor.localIdA01432-
dc.contributor.localIdA03055-
dc.contributor.localIdA03323-
dc.contributor.localIdA04680-
dc.relation.journalcodeJ03512-
dc.identifier.eissn2234-943X-
dc.identifier.pmid33791216-
dc.subject.keyword3D printing-
dc.subject.keywordINTRABEAM™-
dc.subject.keywordbreast cancer-
dc.subject.keywordintraoperative radiation therapy (IORT)-
dc.subject.keywordpatient-specific quality assurance-
dc.contributor.alternativeNameKim, Jun Won-
dc.contributor.affiliatedAuthor김준원-
dc.contributor.affiliatedAuthor박광우-
dc.contributor.affiliatedAuthor이익재-
dc.contributor.affiliatedAuthor이호-
dc.contributor.affiliatedAuthor조연아-
dc.citation.volume11-
dc.citation.startPage629927-
dc.identifier.bibliographicCitationFRONTIERS IN ONCOLOGY, Vol.11 : 629927, 2021-03-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.