340 382

Cited 5 times in

Influence of Edentulous Conditions on Intraoral Scanning Accuracy of Virtual Interocclusal Record in Quadrant Scan

DC Field Value Language
dc.contributor.author김종은-
dc.contributor.author심준성-
dc.contributor.author이근우-
dc.contributor.author이예찬-
dc.date.accessioned2021-04-29T16:58:36Z-
dc.date.available2021-04-29T16:58:36Z-
dc.date.issued2021-02-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/182117-
dc.description.abstractReproduction of the exact interocclusal relationship using digital workflow is crucial for precise fabrication of accurate prostheses. Intraoral scanner is known to be valid for the measurement of quadrants, however, the role of missing area in the quadrant scan on the virtual interocclusal record (VIR) is uncertain. This study aimed to evaluate the accuracy of VIR in quadrant scans using an intraoral scanner (IOS) under four different edentulous conditions. Eight scans per group were obtained using a laboratory scanner and three IOSs (Trios3, CS3600, i500). Based on trueness and precision, Trios3 had the best results, followed by CS3600 and i500. The trueness and precision were affected by edentulous conditions. The three IOSs showed deviation in the posterior region during assessment of VIR for the missing area with posterior support. CS3600 and i500 showed deviation in the short-span edentulous area without support. In extended edentulous condition without support, Trios3 showed overclosure, while i500 showed an angular deviation. In some groups scanned with Trios3 and i500, the tilting effect was observed. Based on the edentulous condition and type of IOS used, local or general deviations in occlusion were seen. The accuracy of VIR was dependent on accurate scan data. Thus, registration of the occlusal relationship in an edentulous area with more than two missing teeth using IOSs may be clinically more inaccurate than that with a laboratory scanner.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherMDPI AG-
dc.relation.isPartOfAPPLIED SCIENCES-BASEL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleInfluence of Edentulous Conditions on Intraoral Scanning Accuracy of Virtual Interocclusal Record in Quadrant Scan-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학교실)-
dc.contributor.googleauthorYe-Chan Lee-
dc.contributor.googleauthorJong-Eun Kim-
dc.contributor.googleauthorNa-Eun Nam-
dc.contributor.googleauthorSeung-Ho Shin-
dc.contributor.googleauthorJung-Hwa Lim-
dc.contributor.googleauthorKeun-Woo Lee-
dc.contributor.googleauthorJune-Sung Shim-
dc.identifier.doi10.3390/app11041489-
dc.contributor.localIdA00927-
dc.contributor.localIdA02211-
dc.contributor.localIdA02688-
dc.contributor.localIdA06025-
dc.relation.journalcodeJ03706-
dc.identifier.eissn2076-3417-
dc.subject.keywordintraoral scanners-
dc.subject.keywordvirtual interocclusal record-
dc.subject.keyworddigital dentistry-
dc.subject.keywordquadrant scan-
dc.subject.keywordCAD/CAM-
dc.contributor.alternativeNameKim, Jong Eun-
dc.contributor.affiliatedAuthor김종은-
dc.contributor.affiliatedAuthor심준성-
dc.contributor.affiliatedAuthor이근우-
dc.contributor.affiliatedAuthor이예찬-
dc.citation.volume11-
dc.citation.number4-
dc.citation.startPage1489-
dc.identifier.bibliographicCitationAPPLIED SCIENCES-BASEL, Vol.11(4) : 1489, 2021-02-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.