Diagnosis of severe sepsis using phospholipids enzymatic assay based on cyclic voltammetry

DC Field Value Language
dc.contributor.author구남수-
dc.contributor.author박광환-
dc.contributor.author박무석-
dc.contributor.author이상국-
dc.contributor.author이은혜-
dc.date.accessioned2021-04-29T16:42:14Z-
dc.date.available2021-04-29T16:42:14Z-
dc.date.issued2021-03-
dc.identifier.issn0141-0229-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/181973-
dc.description.abstractIn this work phospholipid quantification was carried out using an enzymatic assay based on cyclic voltammetry of the condensation product of N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline sodium salt (DAOS) and 4-aminoantipyrine (4-AP) with a graphite electrode. For the optimization of electrochemical measurement for the product, electrochemical properties such as the electrochemical window, double layer capacitance (Cdl) and electron transfer rate (kapp) were analyzed for a graphite-electrode and Au-electrode. The phospholipid enzymatic assay based the on electrochemical measurement using the graphite electrode was applied to the diagnosis of sepsis for sera from healthy volunteers (n = 16), patients with systemic inflammatory response syndrome (SIRS, n = 16) and severe sepsis patients (n = 24). Finally, the phospholipid quantification results from the electrochemical measurement were statistically compared with the conventional method based on optical density measurement.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherElsevier-
dc.relation.isPartOfENZYME AND MICROBIAL TECHNOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleDiagnosis of severe sepsis using phospholipids enzymatic assay based on cyclic voltammetry-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorJun-Hee Park-
dc.contributor.googleauthorJong-Min Park-
dc.contributor.googleauthorGa-Yeon Lee-
dc.contributor.googleauthorZhiquan Song-
dc.contributor.googleauthorJeong Soo Sung-
dc.contributor.googleauthorMin-Jung Kang-
dc.contributor.googleauthorNam Su Ku-
dc.contributor.googleauthorEun Hye Lee-
dc.contributor.googleauthorKwang Hwan Park-
dc.contributor.googleauthorMoo Suk Park-
dc.contributor.googleauthorSang-Guk Lee-
dc.contributor.googleauthorJae-Chul Pyun-
dc.identifier.doi10.1016/j.enzmictec.2020.109728-
dc.contributor.localIdA00189-
dc.contributor.localIdA01437-
dc.contributor.localIdA01457-
dc.contributor.localIdA02810-
dc.contributor.localIdA03053-
dc.relation.journalcodeJ00790-
dc.identifier.eissn1879-0909-
dc.identifier.pmid33541571-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0141022920302210-
dc.subject.keywordCyclic voltammetry-
dc.subject.keywordDiagnosis-
dc.subject.keywordEnzymatic assay-
dc.subject.keywordGraphite-
dc.subject.keywordPhospholipid-
dc.subject.keywordSepsis-
dc.contributor.alternativeNameKu, Nam Su-
dc.contributor.affiliatedAuthor구남수-
dc.contributor.affiliatedAuthor박광환-
dc.contributor.affiliatedAuthor박무석-
dc.contributor.affiliatedAuthor이상국-
dc.contributor.affiliatedAuthor이은혜-
dc.citation.volume144-
dc.citation.startPage109728-
dc.identifier.bibliographicCitationENZYME AND MICROBIAL TECHNOLOGY, Vol.144 : 109728, 2021-03-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.