236 625

Cited 0 times in

엔도크라운 디지털 인상을 위한 구강스캐너 3종의 정확도 평가: 실험실 연구

DC Field Value Language
dc.contributor.authorÇağrı Ural-
dc.contributor.author박지만-
dc.contributor.authorNecati Kaleli-
dc.contributor.authorEsma Çağlayan-
dc.date.accessioned2021-03-17T09:22:13Z-
dc.date.available2021-03-17T09:22:13Z-
dc.date.created2021-03-15-
dc.date.issued2020-10-
dc.identifier.issn0301-2875-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/181805-
dc.description.abstractPurpose: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (IOSs) on digital impressions of different types of endocrown cavity preparations. Materials and methods: Two human mandibular molar teeth were prepared with different endocrown abutment designs: one with a buccal wall (Class 2) and the other without a buccal wall (Class 3). Both cavity designs were scanned using a reference desktop scanner (E3) and three different intraoral scanners: Trios3 (TRI group), Cerec Omnicam (CER group), and i500 (I5 group). The obtained Standard Tessellation Language (.stl) datasets were exported to metrology software. The precision was evaluated based on deviations among repeated scan models recorded by each IOS. The trueness was evaluated based on deviations between the reference data and repeated scans. For detecting interaction, data were statistically analyzed using a univariate analysis of variance (ANOVA) and for analyzing the comparison of the test groups data were analyzed by one-way ANOVA and post-hoc Tukey test at the significance level of .05. Results: The deviation values for both cavity designs in the I5 group were significantly lower than those in the other IOS groups in terms of trueness. For both cavity designs, the TRI group exhibited better precision than the other IOS groups. Conclusion: Different technologies of IOS device’s and different endocrown prepration designs affected the accuracy of the digital scans.-
dc.formatapplication/pdf-
dc.language영어-
dc.publisher대한치과보철학회-
dc.relation.isPartOfJournal of Korean Academy of Prosthodontics (대한치과보철학회지)-
dc.title엔도크라운 디지털 인상을 위한 구강스캐너 3종의 정확도 평가: 실험실 연구-
dc.title.alternativeEvaluation of the accuracy of three different intraoral scanners for endocrown digital impression: An in vitro study-
dc.typeArticle-
dc.contributor.googleauthorÇağrı Ural-
dc.contributor.googleauthor박지만-
dc.contributor.googleauthorNecati Kaleli-
dc.contributor.googleauthorEsma Çağlayan-
dc.identifier.doi10.4047/jkap.2020.58.4.282-
dc.relation.journalcodeJ01493-
dc.identifier.eissn2005-3789-
dc.subject.keywordCavity design-
dc.subject.keywordEndocrown-
dc.subject.keywordIntraoral scanners-
dc.subject.keywordPrecision-
dc.subject.keywordTrueness-
dc.subject.keyword와동 형태-
dc.subject.keyword엔도크라운-
dc.subject.keyword구강스캐너-
dc.subject.keyword정밀도-
dc.subject.keyword진도-
dc.contributor.affiliatedAuthor박지만-
dc.citation.titleJournal of Korean Academy of Prosthodontics (대한치과보철학회지)-
dc.citation.titleJournal of Korean Academy of Prosthodontics-
dc.citation.volume58-
dc.citation.number4-
dc.citation.startPage282-
dc.citation.endPage289-
dc.identifier.bibliographicCitationJournal of Korean Academy of Prosthodontics (대한치과보철학회지), Vol.58(4) : 282-289, 2020-10-
dc.identifier.rimsid67805-
dc.type.rimsART-
dc.description.journalClass2-
dc.description.journalClass2-
dc.subject.keywordAuthorCavity design-
dc.subject.keywordAuthorEndocrown-
dc.subject.keywordAuthorIntraoral scanners-
dc.subject.keywordAuthorPrecision-
dc.subject.keywordAuthorTrueness-
dc.subject.keywordAuthor와동 형태-
dc.subject.keywordAuthor엔도크라운-
dc.subject.keywordAuthor구강스캐너-
dc.subject.keywordAuthor정밀도-
dc.subject.keywordAuthor진도-
dc.identifier.kciidART002638670-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.