206 434

Cited 2 times in

Bioelectrical Impedance Analysis Is Not Sufficient for Determining Water Deficit in Hypernatremic Patients

DC Field Value Language
dc.contributor.author김슬기-
dc.date.accessioned2021-03-03T00:49:33Z-
dc.date.available2021-03-03T00:49:33Z-
dc.date.issued2019-11-
dc.identifier.issn1234-1010-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/181741-
dc.description.abstractBACKGROUND Hypernatremia is associated with poor outcomes in critically ill patients, and an accurate assessment of water volume is important to determine appropriate fluid hydration. Bioelectrical impedance analysis (BIA) is a new, noninvasive, and relatively easy method for measuring hydration status. This study aimed to investigate whether bioelectrical impedance measurements of body water could reduce the frequency of blood sampling for fluid replacement in patients with hypernatremia. MATERIAL AND METHODS Fifty-one hospitalized patients were studied with hypernatremia, defined as a serum sodium ≥150 mmol/L determined by laboratory testing. Laboratory and BIA measurements were compared, and water deficiency was calculated with a conventional formula (sodium-corrected Watson formula) and measured by BIA. RESULTS The value of the absolute fluid overload (AFO) equivalent to the overhydration (OH) value, determined using BIA, did not accurately represent water deficit in patients with hypernatremia (r=0.137, P=0.347). Although the total body water (TBW) measured by BIA showed a significant correlation with that determined by the conventional formula (r=0.861, P<0.001), there was a proportional bias (r=0.617, P<0.001). The intracellular water (ICW) measured by BIA underestimated the TBW level calculated by the conventional formula by about 14.06±4.0 L in the Bland-Altman analysis. CONCLUSIONS It is not currently possible to replace blood testing with BIA for assessing volume status in hypernatremic patients. However, ICW value measured by BIA might represent plasma sodium level more accurately than extracellular water (ECW) or TBW value in patients with hypernatremia.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherInternational Scientific Information-
dc.relation.isPartOfMEDICAL SCIENCE MONITOR-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAdult-
dc.subject.MESHBody Composition-
dc.subject.MESHBody Water / physiology-
dc.subject.MESHDehydration / diagnosis-
dc.subject.MESHElectric Impedance-
dc.subject.MESHExtracellular Space-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHHypernatremia / diagnosis*-
dc.subject.MESHHypernatremia / metabolism*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHOrganism Hydration Status / physiology*-
dc.subject.MESHWater-
dc.titleBioelectrical Impedance Analysis Is Not Sufficient for Determining Water Deficit in Hypernatremic Patients-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorSe-Hee Yoon-
dc.contributor.googleauthorSeul-Gi Kim-
dc.contributor.googleauthorIn-Beom Jeong-
dc.contributor.googleauthorWon-Min Hwang-
dc.contributor.googleauthorSung-Ro Yun-
dc.identifier.doi10.12659/MSM.918095-
dc.contributor.localIdA06026-
dc.relation.journalcodeJ03024-
dc.identifier.eissn1643-3750-
dc.identifier.pmid31705647-
dc.contributor.alternativeNameKim, Seul-gi-
dc.contributor.affiliatedAuthor김슬기-
dc.citation.volume25-
dc.citation.startPage8438-
dc.citation.endPage8446-
dc.identifier.bibliographicCitationMEDICAL SCIENCE MONITOR, Vol.25 : 8438-8446, 2019-11-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.