Cited 2 times in
Sensitivity of radio-photoluminescence glass dosimeters to accumulated doses
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김동욱 | - |
dc.contributor.author | 김지훈 | - |
dc.contributor.author | 김진성 | - |
dc.contributor.author | 김호진 | - |
dc.contributor.author | 박광우 | - |
dc.contributor.author | 장경환 | - |
dc.contributor.author | 한민철 | - |
dc.contributor.author | 한수철 | - |
dc.contributor.author | 신한백 | - |
dc.date.accessioned | 2021-01-19T07:45:36Z | - |
dc.date.available | 2021-01-19T07:45:36Z | - |
dc.date.issued | 2020-12 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/181321 | - |
dc.description.abstract | Background: This study investigated the effect of accumulated doses on radio-photoluminescence glass dosimeters (RPLGDs) from measurements involving mega-voltage photons. Methods: Forty-five commercially available RPLGDs were irradiated to estimate their dose responses. Photon beams of 6, 10, and 15 MV were irradiated onto the RPLGDs inside a phantom, which were divided into five groups with different doses and energies. Groups 1 and 2 were irradiated at 1, 5, 10, 50, and 100 Gy in a sequential manner; Group 3 was irradiated 10 times with a dose of 10 Gy; and Groups 4 and 5 followed the same method as that of Group 3, but with doses of 50 Gy and 100 Gy, respectively. Each device was subjected to a measurement reading procedure each time irradiation. Results: For the annealed Group 1, RPLGD exhibited a linearity response with variance within 5%. For the non-annealed Group 2, readings demonstrated hyperlinearity at 6 MV and 10 MV, and linearity at 15 MV. Following the 100 Gy irradiation, the readings for Group 2 were 118.7 ± 1.9%, 112.2 ± 2.7%, and 101.5 ± 2.3% at 6, 10, and 15 MV, respectively. For Groups 3, 4, and 5, the responsiveness of the RPLGDs gradually decreased as the number of repeated irradiations increased. The percentage readings for the 10th beam irradiation with respect to the readings for the primary beam irradiation were 84.6 ± 1.9%, 87.5 ± 2.4%, and 93.0 ± 3.0% at 6 MV, 10 MV, and 15 MV, respectively. Conclusions: The non-annealed RPLGD response to dose was hyperlinear for the 6 MV and 10 MV photon beams but not for the 15 MV photon beam. Additionally, the annealed RPLGD exhibited a fading phenomenon when the measurement was repeated several times and demonstrated a relatively large fading effect at low energies than at high energies. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.language | English | - |
dc.publisher | Public Library of Science | - |
dc.relation.isPartOf | PLOS ONE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Glass | - |
dc.subject.MESH | Phantoms, Imaging | - |
dc.subject.MESH | Photons | - |
dc.subject.MESH | Radiation Dosage | - |
dc.subject.MESH | Radiation Dosimeters* | - |
dc.subject.MESH | Radiotherapy Dosage | - |
dc.subject.MESH | Sensitivity and Specificity | - |
dc.title | Sensitivity of radio-photoluminescence glass dosimeters to accumulated doses | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiation Oncology (방사선종양학교실) | - |
dc.contributor.googleauthor | Dong Wook Kim | - |
dc.contributor.googleauthor | Jiwon Sung | - |
dc.contributor.googleauthor | Jaeman Son | - |
dc.contributor.googleauthor | Han-Back Shin | - |
dc.contributor.googleauthor | Min-Joo Kim | - |
dc.contributor.googleauthor | Yu-Yun Noh | - |
dc.contributor.googleauthor | Hojae Kim | - |
dc.contributor.googleauthor | Min Cheol Han | - |
dc.contributor.googleauthor | Jihun Kim | - |
dc.contributor.googleauthor | Su Chul Han | - |
dc.contributor.googleauthor | Kyung Hwan Chang | - |
dc.contributor.googleauthor | Hojin Kim | - |
dc.contributor.googleauthor | Kwangwoo Park | - |
dc.contributor.googleauthor | Myonggeun Yoon | - |
dc.contributor.googleauthor | Jinsung Kim | - |
dc.contributor.googleauthor | Dongho Shin | - |
dc.identifier.doi | 10.1371/journal.pone.0234829 | - |
dc.contributor.localId | A05710 | - |
dc.contributor.localId | A05823 | - |
dc.contributor.localId | A04548 | - |
dc.contributor.localId | A05970 | - |
dc.contributor.localId | A01432 | - |
dc.contributor.localId | A05840 | - |
dc.contributor.localId | A05870 | - |
dc.contributor.localId | A05942 | - |
dc.relation.journalcode | J02540 | - |
dc.identifier.eissn | 1932-6203 | - |
dc.identifier.pmid | 33270667 | - |
dc.contributor.alternativeName | Kim, Dong Wook | - |
dc.contributor.affiliatedAuthor | 김동욱 | - |
dc.contributor.affiliatedAuthor | 김지훈 | - |
dc.contributor.affiliatedAuthor | 김진성 | - |
dc.contributor.affiliatedAuthor | 김호진 | - |
dc.contributor.affiliatedAuthor | 박광우 | - |
dc.contributor.affiliatedAuthor | 장경환 | - |
dc.contributor.affiliatedAuthor | 한민철 | - |
dc.contributor.affiliatedAuthor | 한수철 | - |
dc.citation.volume | 15 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | e0234829 | - |
dc.identifier.bibliographicCitation | PLOS ONE, Vol.15(12) : e0234829, 2020-12 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.