dc.description.abstractBackground: This study investigated the effect of accumulated doses on radio-photoluminescence glass dosimeters (RPLGDs) from measurements involving mega-voltage photons. Methods: Forty-five commercially available RPLGDs were irradiated to estimate their dose responses. Photon beams of 6, 10, and 15 MV were irradiated onto the RPLGDs inside a phantom, which were divided into five groups with different doses and energies. Groups 1 and 2 were irradiated at 1, 5, 10, 50, and 100 Gy in a sequential manner; Group 3 was irradiated 10 times with a dose of 10 Gy; and Groups 4 and 5 followed the same method as that of Group 3, but with doses of 50 Gy and 100 Gy, respectively. Each device was subjected to a measurement reading procedure each time irradiation. Results: For the annealed Group 1, RPLGD exhibited a linearity response with variance within 5%. For the non-annealed Group 2, readings demonstrated hyperlinearity at 6 MV and 10 MV, and linearity at 15 MV. Following the 100 Gy irradiation, the readings for Group 2 were 118.7 ± 1.9%, 112.2 ± 2.7%, and 101.5 ± 2.3% at 6, 10, and 15 MV, respectively. For Groups 3, 4, and 5, the responsiveness of the RPLGDs gradually decreased as the number of repeated irradiations increased. The percentage readings for the 10th beam irradiation with respect to the readings for the primary beam irradiation were 84.6 ± 1.9%, 87.5 ± 2.4%, and 93.0 ± 3.0% at 6 MV, 10 MV, and 15 MV, respectively. Conclusions: The non-annealed RPLGD response to dose was hyperlinear for the 6 MV and 10 MV photon beams but not for the 15 MV photon beam. Additionally, the annealed RPLGD exhibited a fading phenomenon when the measurement was repeated several times and demonstrated a relatively large fading effect at low energies than at high energies.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherPublic Library of Science-
dc.relation.isPartOfPLOS ONE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHGlass-
dc.subject.MESHPhantoms, Imaging-
dc.subject.MESHPhotons-
dc.subject.MESHRadiation Dosage-
dc.subject.MESHRadiation Dosimeters*-
dc.subject.MESHRadiotherapy Dosage-
dc.subject.MESHSensitivity and Specificity-
dc.titleSensitivity of radio-photoluminescence glass dosimeters to accumulated doses-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorDong Wook Kim-
dc.contributor.googleauthorJiwon Sung-
dc.contributor.googleauthorJaeman Son-
dc.contributor.googleauthorHan-Back Shin-
dc.contributor.googleauthorMin-Joo Kim-
dc.contributor.googleauthorYu-Yun Noh-
dc.contributor.googleauthorHojae Kim-
dc.contributor.googleauthorMin Cheol Han-
dc.contributor.googleauthorJihun Kim-
dc.contributor.googleauthorSu Chul Han-
dc.contributor.googleauthorKyung Hwan Chang-
dc.contributor.googleauthorHojin Kim-
dc.contributor.googleauthorKwangwoo Park-
dc.contributor.googleauthorMyonggeun Yoon-
dc.contributor.googleauthorJinsung Kim-
dc.contributor.googleauthorDongho Shin-
dc.identifier.doi10.1371/journal.pone.0234829-
dc.contributor.localIdA05710-
dc.contributor.localIdA05823-
dc.contributor.localIdA04548-
dc.contributor.localIdA05970-
dc.contributor.localIdA01432-
dc.contributor.localIdA05840-
dc.contributor.localIdA05870-
dc.contributor.localIdA05942-
dc.relation.journalcodeJ02540-
dc.identifier.eissn1932-6203-
dc.identifier.pmid33270667-
dc.contributor.alternativeNameKim, Dong Wook-
dc.contributor.affiliatedAuthor김동욱-
dc.contributor.affiliatedAuthor김지훈-
dc.contributor.affiliatedAuthor김진성-
dc.contributor.affiliatedAuthor김호진-
dc.contributor.affiliatedAuthor박광우-
dc.contributor.affiliatedAuthor장경환-
dc.contributor.affiliatedAuthor한민철-
dc.contributor.affiliatedAuthor한수철-
dc.citation.volume15-
dc.citation.number12-
dc.citation.startPagee0234829-
dc.identifier.bibliographicCitationPLOS ONE, Vol.15(12) : e0234829, 2020-12-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.