Cited 6 times in
Clinical Experience of Vibroplasty With Direct Coupling to the Oval Window Without Use of a Coupler
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김성헌 | - |
dc.contributor.author | 남기성 | - |
dc.contributor.author | 배성훈 | - |
dc.contributor.author | 정진세 | - |
dc.contributor.author | 최재영 | - |
dc.date.accessioned | 2020-12-11T07:54:50Z | - |
dc.date.available | 2020-12-11T07:54:50Z | - |
dc.date.issued | 2020-12 | - |
dc.identifier.issn | 0023-852X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/180707 | - |
dc.description.abstract | Objectives/hypothesis: To investigate the efficacy of direct implantation of a Vibrant Soundbridge (VSB) implant in the oval window (OW) without the use of an OW coupler in patients with severe mixed hearing loss. Study design: Retrospective chart review METHODS: A total of 62 patients underwent VSB implantation between July 2016 and December 2018 at Severance Hospital in Seoul, South Korea. Among them, eight patients (nine ears) with moderate-to-severe mixed hearing loss were implanted with a VSB directly in the OW. A floating mass transducer (FMT) was attached to the stapes footplate and covered with tragal cartilage. The outcomes were evaluated using pure-tone audiogram and speech audiogram preoperatively and postoperatively. Word recognition score (WRS; % correct) were measured at the most comfortable loudness (MCL) level to evaluate speech perception. Results: All cases posed difficulty with round window vibroplasty during surgery, and eventually, an FMT was appropriately placed in the OW without a coupler. Preoperative and postoperative bone conduction thresholds were not different. VSB-aided threshold improved in terms of functional and effective gains. Interestingly, four cases showed improved air conduction thresholds without the use of a VSB. In addition, MCL level with a VSB was significantly lower than that with a hearing aid, and VSB-aided WRS improved over time. Conclusions: Direct implantation of a VSB in the OW without the use of a coupler showed favorable hearing outcomes, and the OW vibroplasty was safe. Direct OW vibroplasty without a coupler is a reliable procedure and can be a good option for hearing rehabilitation in patients with severe mixed hearing loss. Level of evidence: 4 Laryngoscope, 2020. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Wiley-Blackwell | - |
dc.relation.isPartOf | LARYNGOSCOPE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Clinical Experience of Vibroplasty With Direct Coupling to the Oval Window Without Use of a Coupler | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Otorhinolaryngology (이비인후과학교실) | - |
dc.contributor.googleauthor | Sang Hyun Kwak | - |
dc.contributor.googleauthor | Young Min Moon | - |
dc.contributor.googleauthor | Gi-Sung Nam | - |
dc.contributor.googleauthor | Seong Hoon Bae | - |
dc.contributor.googleauthor | Sung Huhn Kim | - |
dc.contributor.googleauthor | Jinsei Jung | - |
dc.contributor.googleauthor | Jae Young Choi | - |
dc.identifier.doi | 10.1002/lary.28514 | - |
dc.contributor.localId | A00589 | - |
dc.contributor.localId | A05622 | - |
dc.contributor.localId | A05563 | - |
dc.contributor.localId | A03742 | - |
dc.contributor.localId | A04173 | - |
dc.relation.journalcode | J02156 | - |
dc.identifier.eissn | 1531-4995 | - |
dc.identifier.pmid | 31977072 | - |
dc.identifier.url | https://onlinelibrary.wiley.com/doi/10.1002/lary.28514 | - |
dc.subject.keyword | Vibrant Soundbridge | - |
dc.subject.keyword | hearing rehabilitation | - |
dc.subject.keyword | oval window coupler | - |
dc.subject.keyword | severe mixed hearing loss | - |
dc.contributor.alternativeName | Kim, Sung Huhn | - |
dc.contributor.affiliatedAuthor | 김성헌 | - |
dc.contributor.affiliatedAuthor | 남기성 | - |
dc.contributor.affiliatedAuthor | 배성훈 | - |
dc.contributor.affiliatedAuthor | 정진세 | - |
dc.contributor.affiliatedAuthor | 최재영 | - |
dc.citation.volume | 130 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | E926 | - |
dc.citation.endPage | E932 | - |
dc.identifier.bibliographicCitation | LARYNGOSCOPE, Vol.130(12) : E926-E932, 2020-12 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.