Cited 13 times in
Biomechanical comparison of the angle of inserted screws and the length of anterior cervical plate systems with allograft spacers
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 문성환 | - |
dc.contributor.author | 이병호 | - |
dc.contributor.author | 이환모 | - |
dc.contributor.author | 권지원 | - |
dc.date.accessioned | 2020-12-11T07:54:06Z | - |
dc.date.available | 2020-12-11T07:54:06Z | - |
dc.date.issued | 2020-06 | - |
dc.identifier.issn | 0268-0033 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/180702 | - |
dc.description.abstract | Background: Comparative studies of the biomechanical effects of plates of varying lengths and different screw insertion angles on allograft spacers are lacking. Methods: Finite element model analysis of a previously validated, three-dimensional, intact cervical spinal segment model of C3-6 was conducted in the present study. On the C5-6 segment, anterior discectomy and fusion were performed using allograft spacers and different combinations of anterior plates and screws. The biomechanical characteristics of combinations of short, medium, and maximal length plates with screw insertion angles of 0°, 8°, 16°, and 32° were analyzed. Findings: In flexion and extension, the risk of allograft spacer subsidence decreased as screw angles increased. Short plates with a screw insertion angle of 32° posed the lowest subsidence risk, similar to medium length plates with a screw insertion angle of 16°, in all motion conditions. The risk of bone yielding increased as plate length increased, but decreased as the screw insertion angle increased. Interpretation: Short plates with a large screw insertion angle (32°) showed the highest mechanical stability and load sharing of allograft spacers and the lowest risk of screw loosening. Accordingly, we recommend the use of a short plate and large screw insertion angle for anterior cervical discectomy and fusion. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Elsevier Science | - |
dc.relation.isPartOf | CLINICAL BIOMECHANICS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Biomechanical comparison of the angle of inserted screws and the length of anterior cervical plate systems with allograft spacers | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Orthopedic Surgery (정형외과학교실) | - |
dc.contributor.googleauthor | Ji-Won Kwon | - |
dc.contributor.googleauthor | Sun-Hee Bang | - |
dc.contributor.googleauthor | Young-Woo Kwon | - |
dc.contributor.googleauthor | Jae-Yong Cho | - |
dc.contributor.googleauthor | Tae-Hyun Park | - |
dc.contributor.googleauthor | Sung-Jae Lee | - |
dc.contributor.googleauthor | Hwan-Mo Lee | - |
dc.contributor.googleauthor | Seong-Hwan Moon | - |
dc.contributor.googleauthor | Byung Ho Lee | - |
dc.identifier.doi | 10.1016/j.clinbiomech.2020.105021 | - |
dc.contributor.localId | A01365 | - |
dc.contributor.localId | A02801 | - |
dc.contributor.localId | A03333 | - |
dc.relation.journalcode | J03918 | - |
dc.identifier.eissn | 1879-1271 | - |
dc.identifier.pmid | 32416405 | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0268003320301303 | - |
dc.subject.keyword | Allograft spacers | - |
dc.subject.keyword | Anterior cervical discectomy | - |
dc.subject.keyword | Finite element mode | - |
dc.subject.keyword | Plate | - |
dc.subject.keyword | Screw | - |
dc.contributor.alternativeName | Moon, Seong Hwan | - |
dc.contributor.affiliatedAuthor | 문성환 | - |
dc.contributor.affiliatedAuthor | 이병호 | - |
dc.contributor.affiliatedAuthor | 이환모 | - |
dc.citation.volume | 76 | - |
dc.citation.startPage | 105021 | - |
dc.identifier.bibliographicCitation | CLINICAL BIOMECHANICS, Vol.76 : 105021, 2020-06 | - |
dc.identifier.rimsid | 67305 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.