216 517

Cited 2 times in

Simple calculation using anatomical features on pre-treatment verification CT for bladder volume estimation during radiation therapy for rectal cancer

DC Field Value Language
dc.contributor.author금웅섭-
dc.contributor.author김나리-
dc.contributor.author김진성-
dc.contributor.author윤홍인-
dc.contributor.author장지석-
dc.date.accessioned2020-12-01T17:37:01Z-
dc.date.available2020-12-01T17:37:01Z-
dc.date.issued2020-10-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/180352-
dc.description.abstractBackground: Despite detailed instruction for full bladder, patients are unable to maintain consistent bladder filling during a 5-week pelvic radiation therapy (RT) course. We investigated the best bladder volume estimation procedure for verifying consistent bladder volume. Methods: We reviewed 462 patients who underwent pelvic RT. Biofeedback using a bladder scanner was conducted before simulation and during treatment. Exact bladder volume was calculated by bladder inner wall contour based on CT images (Vctsim). Bladder volume was estimated either by bladder scanner (Vscan) or anatomical features from the presacral promontory to the bladder base and dome in the sagittal plane of CT (Vratio). The feasibility of Vratio was validated using daily megavoltage or kV cone-beam CT before treatment. Results: Mean Vctsim was 335.6 ± 147.5 cc. Despite a positive correlation between Vctsim and Vscan (R2 = 0.278) and between Vctsim and Vratio (R2 = 0.424), Vratio yielded more consistent results than Vscan, with a mean percentage error of 26.3 (SD 19.6, p < 0.001). The correlation between Vratio and Vctsim was stronger than that between Vscan and Vctsim (Z-score: - 7.782, p < 0.001). An accuracy of Vratio was consistent in megavoltage or kV cone-beam CT during treatment. In a representative case, we can dichotomize for clinical scenarios with or without bowel displacement, using a ratio of 0.8 resulting in significant changes in bowel volume exposed to low radiation doses. Conclusions: Bladder volume estimation using personalized anatomical features based on pre-treatment verification CT images was useful and more accurate than physician-dependent bladder scanners. Trial registration: Retrospectively registered.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherBioMed Central-
dc.relation.isPartOfBMC CANCER-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleSimple calculation using anatomical features on pre-treatment verification CT for bladder volume estimation during radiation therapy for rectal cancer-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorNalee Kim-
dc.contributor.googleauthorHong In Yoon-
dc.contributor.googleauthorJin Sung Kim-
dc.contributor.googleauthorWoong Sub Koom-
dc.contributor.googleauthorJee Suk Chang-
dc.contributor.googleauthorYoonsun Chung-
dc.identifier.doi10.1186/s12885-020-07405-z-
dc.contributor.localIdA00273-
dc.contributor.localIdA05709-
dc.contributor.localIdA04548-
dc.contributor.localIdA04777-
dc.contributor.localIdA04658-
dc.relation.journalcodeJ00351-
dc.identifier.eissn1471-2407-
dc.identifier.pmid33004026-
dc.subject.keywordBladder volume-
dc.subject.keywordComputed tomography simulation-
dc.subject.keywordCone-beam CT-
dc.subject.keywordMegavoltage CT-
dc.contributor.alternativeNameKoom, Woong Sub-
dc.contributor.affiliatedAuthor금웅섭-
dc.contributor.affiliatedAuthor김나리-
dc.contributor.affiliatedAuthor김진성-
dc.contributor.affiliatedAuthor윤홍인-
dc.contributor.affiliatedAuthor장지석-
dc.citation.volume20-
dc.citation.number1-
dc.citation.startPage942-
dc.identifier.bibliographicCitationBMC CANCER, Vol.20(1) : 942, 2020-10-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.