dc.description.abstract | Clinical outcomes of the dorsal-retrograde headless screw-fixation technique in 15 patients with proximal scaphoid nonunion are presented. In this technique, screws are inserted from the dorsal rough surface of the scaphoid, located between the dorsal ridge and scaphoid-trapezium-trapezoid joint. Fifteen patients underwent osteosynthesis with this technique with iliac bone graft. Seven patients required primary surgery, and eight patients with a history of failed operation required revision surgery. Among 15 patients, 13 achieved union and two with persistent nonunion were asymptomatic with average follow-up of 24 months (range 14-57). Mean time to union was 20 weeks (range 12-40). Our experience with the dorsal-retrograde headless screw fixation technique has shown encouraging results for the treatment of proximal-scaphoid nonunion, especially in revision surgery wherein secure fixation of the small proximal fragments can be difficult using conventional anterograde techniques.Level of evidence: IV. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Sage Publications | - |
dc.relation.isPartOf | JOURNAL OF HAND SURGERY-EUROPEAN VOLUME | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Headless screw fixation through the dorsal rough surface for proximal-pole scaphoid-nonunion: a report of 15 patients | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Orthopedic Surgery (정형외과학교실) | - |
dc.contributor.googleauthor | JungJun Hong | - |
dc.contributor.googleauthor | Yun-Rak Choi | - |
dc.contributor.googleauthor | Il-Hyun Koh | - |
dc.contributor.googleauthor | Won-Taek Oh | - |
dc.contributor.googleauthor | Jucheol Shin | - |
dc.contributor.googleauthor | Ho-Jung Kang | - |
dc.identifier.doi | 10.1177/1753193420903672 | - |
dc.contributor.localId | A00098 | - |
dc.contributor.localId | A00141 | - |
dc.contributor.localId | A02391 | - |
dc.contributor.localId | A04136 | - |
dc.contributor.localId | A05193 | - |
dc.relation.journalcode | J01429 | - |
dc.identifier.eissn | 2043-6289 | - |
dc.identifier.pmid | 32009496 | - |
dc.identifier.url | https://journals.sagepub.com/doi/10.1177/1753193420903672 | - |
dc.subject.keyword | Dorsal rough surface | - |
dc.subject.keyword | dorsal-retrograde technique | - |
dc.subject.keyword | headless screw | - |
dc.subject.keyword | proximal-pole nonunion | - |
dc.subject.keyword | scaphoid | - |
dc.contributor.alternativeName | Kang, Ho Jung | - |
dc.contributor.affiliatedAuthor | 강호정 | - |
dc.contributor.affiliatedAuthor | 고일현 | - |
dc.contributor.affiliatedAuthor | 오원택 | - |
dc.contributor.affiliatedAuthor | 최윤락 | - |
dc.contributor.affiliatedAuthor | 홍정준 | - |
dc.citation.volume | 45 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 965 | - |
dc.citation.endPage | 973 | - |
dc.identifier.bibliographicCitation | JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, Vol.45(9) : 965-973, 2020-11 | - |