Cited 0 times in
Dosimetric effect of MLC speed obtained with machine log files of VMAT delivery
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김지훈 | - |
dc.contributor.author | 김진성 | - |
dc.contributor.author | 박광우 | - |
dc.contributor.author | 이호 | - |
dc.date.accessioned | 2020-12-01T17:06:31Z | - |
dc.date.available | 2020-12-01T17:06:31Z | - |
dc.date.issued | 2020-07 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/180126 | - |
dc.description.abstract | This paper aims to investigate the stability of volumetric modulated arc therapy (VMAT) delivery during treatment using the multi-leaf collimator (MLC) speed recorded in the log files. The mechanical error, such as the position error and speed of the MLC recorded in the log file, affects the dose accuracy of the VMAT delivery. We evaluated the stability of VAMT delivery by determining the relationship between the gamma pass rate (GPR) and MLC speed. The 15 VMAT plans were used to investigate the stability of the beam delivery. The Mobius software calculated the dose distribution by the log files from the planning CT image set. The GPR was evaluated by comparing the reconstructed dose with the planned dose. To validate the gamma analysis calculated from the log file, we compared the results with the GPR measured by the ArcCHECK phantom. A comparison of the GPRs between ArcCHECK and Mobius was performed based on different criteria: 3%/3 mm and 2%/2 mm. Based on the results, we represent that (1) the 2%/2 mm criterion of the Mobius system is comparable to perform the quality assurance (QA) with ArcCHECK using the criterion of 3%/3 mm, and (2) the interfractional variation of the VMAT delivery depends on the distribution of the MLC speed. In this study, we determined that the variation of the GPRs during the whole treatment is less than 2% and the average leaves speed is less than 10 mm/s. These results reveal that the log files are one of the indicators to monitor the variation of VMAT delivery. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | SISSA | - |
dc.relation.isPartOf | JOURNAL OF INSTRUMENTATION | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Dosimetric effect of MLC speed obtained with machine log files of VMAT delivery | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiation Oncology (방사선종양학교실) | - |
dc.contributor.googleauthor | E. Lee | - |
dc.contributor.googleauthor | H. Lee | - |
dc.contributor.googleauthor | J. Kim | - |
dc.contributor.googleauthor | M.J. Kim | - |
dc.contributor.googleauthor | J. Bak | - |
dc.contributor.googleauthor | J.S. Kim | - |
dc.contributor.googleauthor | K. Park | - |
dc.identifier.doi | 10.1088/1748-0221/15/07/P07005 | - |
dc.contributor.localId | A05823 | - |
dc.contributor.localId | A04548 | - |
dc.contributor.localId | A01432 | - |
dc.contributor.localId | A03323 | - |
dc.relation.journalcode | J03636 | - |
dc.identifier.eissn | 1748-0221 | - |
dc.identifier.url | https://iopscience.iop.org/article/10.1088/1748-0221/15/07/P07005/meta | - |
dc.subject.keyword | Radiotherapy concepts | - |
dc.subject.keyword | Dosimetry concepts | - |
dc.subject.keyword | apparatus | - |
dc.contributor.alternativeName | Kim, Jihun | - |
dc.contributor.affiliatedAuthor | 김지훈 | - |
dc.contributor.affiliatedAuthor | 김진성 | - |
dc.contributor.affiliatedAuthor | 박광우 | - |
dc.contributor.affiliatedAuthor | 이호 | - |
dc.citation.volume | 15 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | P07005 | - |
dc.identifier.bibliographicCitation | JOURNAL OF INSTRUMENTATION, Vol.15(7) : P07005, 2020-07 | - |
dc.identifier.rimsid | 67153 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.