102 327

Cited 13 times in

Changes in performance of small bowel capsule endoscopy based on nationwide data from a Korean Capsule Endoscopy Registry

DC Field Value Language
dc.contributor.author천재영-
dc.date.accessioned2020-12-01T16:51:58Z-
dc.date.available2020-12-01T16:51:58Z-
dc.date.issued2020-07-
dc.identifier.issn1226-3303-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/180015-
dc.description.abstractBackground/aims: Capsule endoscopy (CE) is widely used for the diagnosis of small bowel diseases. The clinical performance and complications of small bowel CE, including completion rate, capsule retention rate, and indications, have been previously described in Korea. This study aimed at estimating the recent changes in clinical performance and complications of small bowel CE based on 17-year data from a Korean Capsule Endoscopy Registry. Methods: CE registry data from 35 hospitals were retrospectively analyzed. Clinical information, including completion rate, capsule retention rate, and indications, was collected and analyzed. In addition, the most recent 5-year data for CE examinations were compared with the previous 12-year data. Results: A total of 4,650 CE examinations were analyzed. The most common indication for CE was obscure gastrointestinal bleeding (OGIB). The overall incomplete examination rate was 16% and the capsule retention rate was 3%. Crohn's disease was a risk factor for capsule retention. Inadequate bowel preparation was significantly associated with capsule retention and incomplete examination. An indication other than OGIB was a risk factor for incomplete examination. A recent increasing trend of CE diagnosis of Crohn's disease was observed. The most recent 5-year incomplete examination rate for CE examinations decreased compared with that of the previous 12 years. Conclusion: The 17-year data suggested that CE is a useful and safe tool for diagnosing small bowel diseases. The incomplete examination rate of CE decreased with time, and OGIB was consistently the main indication for CE. Inadequate bowel preparation was significantly associated with capsule retention and incomplete examination.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherKorean Association of Internal Medicine-
dc.relation.isPartOfKOREAN JOURNAL OF INTERNAL MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleChanges in performance of small bowel capsule endoscopy based on nationwide data from a Korean Capsule Endoscopy Registry-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorSu Hwan Kim-
dc.contributor.googleauthorYun Jeong Lim-
dc.contributor.googleauthorJunseok Park-
dc.contributor.googleauthorKi-Nam Shim-
dc.contributor.googleauthorDong-Hoon Yang-
dc.contributor.googleauthorJaeyoung Chun-
dc.contributor.googleauthorJin Su Kim-
dc.contributor.googleauthorHyun Seok Lee-
dc.contributor.googleauthorHoon Jai Chun-
dc.contributor.googleauthorResearch Group for Capsule Endoscopy/Small Bowel Endoscopy-
dc.identifier.doi10.3904/kjim.2019.312-
dc.contributor.localIdA05701-
dc.relation.journalcodeJ02883-
dc.identifier.eissn2005-6648-
dc.identifier.pmid31878772-
dc.subject.keywordBowel preparation-
dc.subject.keywordCapsule endoscopy-
dc.subject.keywordIntestine, small-
dc.subject.keywordRetention-
dc.contributor.alternativeNameCheon, Jae Young-
dc.contributor.affiliatedAuthor천재영-
dc.citation.volume35-
dc.citation.number4-
dc.citation.startPage889-
dc.citation.endPage896-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF INTERNAL MEDICINE, Vol.35(4) : 889-896, 2020-07-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.