Cited 0 times in
인플루엔자 진단을 위한 두 가지 신속검사의 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이상국 | - |
dc.date.accessioned | 2020-12-01T16:47:21Z | - |
dc.date.available | 2020-12-01T16:47:21Z | - |
dc.date.issued | 2020-04 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/179975 | - |
dc.description.abstract | Rapid influenza diagnostic test (RIDT) is widely used for the diagnosis of influenza owing to its simplicity and convenience of use. This study aimed to evaluate the performance of a new RIDT, SD Standard F influenza A/B FIA (SD Biosensor, Inc., Korea) (Standard F) and compare its performance with BD Veritor Flu A+B (Veritor), using the results of real-time reverse transcription PCR (rRT-PCR) analysis as the standard for reference. On comparing the results obtained from both the RIDTs and rRT-PCR qualitatively, it was found that the Veritor and Standard F assays have the sensitivity of 65.6% (21/32) and 71.9% (23/32), respectively, for the detection of influenza A with a specificity of 100.0% (68/68). Additionally, both the assays demonstrated a sensitivity of 66.7% (12/18) and specificity of 100.0% (68/68) for the detection of influenza B. The cutoff index (COI) value of the fluorescence color intensity from the Standard F assay, displayed on the device along with the qualitative results, indicated a negative correlation with the Ct value from rRT-PCR for both influenza A and B (P<0.001). The sensitivity of the new RIDT for the detection of influenza was comparable with that of the Veritor assay and the new RIDT could be used as a substitute for existing RIDTs by providing additional information to predict the approximate viral burden of influenza. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | Korean Society for Laboratory Medicine | - |
dc.relation.isPartOf | Laboratory Medicine Online | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | 인플루엔자 진단을 위한 두 가지 신속검사의 평가 | - |
dc.title.alternative | Evaluating the Diagnostic Performance of Two Rapid Influenza Diagnostic Tests | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Laboratory Medicine (진단검사의학교실) | - |
dc.contributor.googleauthor | 김진주 | - |
dc.contributor.googleauthor | 조용근 | - |
dc.contributor.googleauthor | 이상국 | - |
dc.identifier.doi | 10.3343/lmo.2020.10.2.160 | - |
dc.contributor.localId | A02810 | - |
dc.relation.journalcode | J02151 | - |
dc.identifier.eissn | 2093-6338 | - |
dc.subject.keyword | Influenza | - |
dc.subject.keyword | Rapid diagnostic test | - |
dc.subject.keyword | Evaluation | - |
dc.subject.keyword | BD Veritor | - |
dc.subject.keyword | SD Standard F | - |
dc.contributor.alternativeName | Lee, Sang Guk | - |
dc.contributor.affiliatedAuthor | 이상국 | - |
dc.citation.volume | 10 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 160 | - |
dc.citation.endPage | 164 | - |
dc.identifier.bibliographicCitation | Laboratory Medicine Online, Vol.10(2) : 160-164, 2020-04 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.