Cited 97 times in
Effects of Scanning Strategy and Scanner Type on the Accuracy of Intraoral Scans: A New Approach for Assessing the Accuracy of Scanned Data
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박지만 | - |
dc.contributor.author | 오경철 | - |
dc.contributor.author | 문홍석 | - |
dc.date.accessioned | 2020-09-29T01:14:13Z | - |
dc.date.available | 2020-09-29T01:14:13Z | - |
dc.date.issued | 2020-06 | - |
dc.identifier.issn | 1059-941X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/179448 | - |
dc.description.abstract | Purpose: This study aimed to determine the most reliable scanning strategy and scanner type, using a new protocol for assessing the accuracy (trueness and precision) of intraoral scan data. Materials and methods: Five different maxillary and mandibular typodont pairs (n = 10) and 2 intraoral scanners were used for the study. A reference scan for each arch was obtained with an industrial scanner. Scanning strategies were classified into 2 continuous methods-continuous scan in horizontal direction (CH group) and continuous scan with vertical rotation in anterior region (CV group)-and 1 segmental method (S group). In the CH group, the scanner head was maintained mostly in a horizontal position. In the CV group, the scanners were rotated 180° around the anterior tooth region to allow smooth scanning through the area. The intraoral scan data were individually superimposed over their corresponding reference scan data. Raw data of the distances between paired surface points were extracted from the superimposed pairs of datasets, with (original distance values) or without consideration (absolute distance values) of the value signs. Trueness values were calculated using absolute distance values, while precision values were obtained from original distance values. Data were analyzed with a 2-way repeated-measures analysis of variance using α = 0.05 as the level of significance. Results: The CV group produced significantly inferior outcomes compared to the CH and S groups in terms of trueness (p < 0.001, F = 24.67), whereas no significant differences were observed among the 3 scanning strategies with respect to precision (p = 0.451, F = 0.83). Scanner type did not produce significant differences in terms of either trueness (p = 0.058, F = 4.72) or precision (p = 0.742, F = 0.12). Conclusions: The segmental approach for scanning the region of interest first and continuous scanning with the scanner head held mostly in a horizontal position are both acceptable as full-arch scanning strategies. However, vertical rotation of intraoral scanners should be minimized. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Wiley-Blackwell | - |
dc.relation.isPartOf | JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Computer-Aided Design | - |
dc.subject.MESH | Dental Impression Technique* | - |
dc.subject.MESH | Dental Models* | - |
dc.subject.MESH | Imaging, Three-Dimensional | - |
dc.subject.MESH | Maxilla | - |
dc.title | Effects of Scanning Strategy and Scanner Type on the Accuracy of Intraoral Scans: A New Approach for Assessing the Accuracy of Scanned Data | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Prosthodontics (보철과학교실) | - |
dc.contributor.googleauthor | Kyung Chul Oh | - |
dc.contributor.googleauthor | Ji-Man Park | - |
dc.contributor.googleauthor | Hong Seok Moon | - |
dc.identifier.doi | 10.1111/jopr.13158 | - |
dc.contributor.localId | A05595 | - |
dc.contributor.localId | A04976 | - |
dc.contributor.localId | A01395 | - |
dc.relation.journalcode | J01719 | - |
dc.identifier.eissn | 1532-849X | - |
dc.identifier.pmid | 32133690 | - |
dc.identifier.url | https://onlinelibrary.wiley.com/doi/full/10.1111/jopr.13158 | - |
dc.subject.keyword | direct digitization | - |
dc.subject.keyword | precision | - |
dc.subject.keyword | scan accuracy | - |
dc.subject.keyword | scanning protocol | - |
dc.subject.keyword | trueness | - |
dc.contributor.alternativeName | Park, Ji-Man | - |
dc.contributor.affiliatedAuthor | 박지만 | - |
dc.contributor.affiliatedAuthor | 오경철 | - |
dc.contributor.affiliatedAuthor | 문홍석 | - |
dc.citation.volume | 29 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 518 | - |
dc.citation.endPage | 523 | - |
dc.identifier.bibliographicCitation | JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, Vol.29(6) : 518-523, 2020-06 | - |
dc.identifier.rimsid | 67208 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.