389 755

Cited 1 times in

Cited 3 times in

TomoMQA: Automated analysis program for MVCT quality assurance of helical tomotherapy

DC Field Value Language
dc.contributor.authorHan, Min Cheol-
dc.contributor.authorHong, Chae-Seon-
dc.contributor.authorChang, Kyung Hwan-
dc.contributor.authorKim, Jihun-
dc.contributor.authorHan, Su Chul-
dc.contributor.authorKim, Dong Wook-
dc.contributor.authorPark, Kwangwoo-
dc.contributor.authorKim, Min-Joo-
dc.contributor.authorShin, Han Back-
dc.contributor.authorLee, Se Hyung-
dc.contributor.authorKim, Jin Sung-
dc.date.accessioned2020-09-28T11:46:45Z-
dc.date.available2020-09-28T11:46:45Z-
dc.date.created2021-03-18-
dc.date.issued2020-06-
dc.identifier.issn1526-9914-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/179288-
dc.description.abstractPurpose In this study, we developed a simple but useful computer program, called TomoMQA, to offer an automated quality assurance for mega-voltage computed tomography (MVCT) images generated via helical tomotherapy. Methods TomoMQA is written in MATLAB and contains three steps for analysis: (a) open the DICOM dataset folder generated via helical tomotherapy (i.e., TomoTherapy(R) and Radixact (TM)), (b) call the baseline data for the consistency test and click the "Analysis" button (or click the "Analysis" button without the baseline data and export the results as the baseline data), and (c) print an analyzed report. The overall procedure for the QA analysis included in TomoMQA is referred from the TG-148 recommendation. Here, the tolerances for MVCT QA were implemented from TG-148 recommended values as default; however, it can be modified by a user manually. Results To test the performance of the TomoMQA program, 15 MVCTs were prepared from five helical tomotherapy machines (1 of TomoTherapy(R) HD, 2 of TomoTherapy(R) HDA, and 2 of Radixact (TM)) in 3 months and the QA procedures were performed using TomoMQA. From our results, the evaluation revealed that the developed program can successfully perform the MVCT QA analysis irrespective of the type of helical tomotherapy equipment. Conclusion We successfully developed a new automated analysis program for MVCT QA of a helical tomotherapy platform, called TomoMQA. The developed program will be made freely downloadable from the TomoMQA-dedicated website.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherWiley-
dc.relation.isPartOfJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS-
dc.relation.isPartOfJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleTomoMQA: Automated analysis program for MVCT quality assurance of helical tomotherapy-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorHan, Min Cheol-
dc.contributor.googleauthorHong, Chae-Seon-
dc.contributor.googleauthorChang, Kyung Hwan-
dc.contributor.googleauthorKim, Jihun-
dc.contributor.googleauthorHan, Su Chul-
dc.contributor.googleauthorKim, Dong Wook-
dc.contributor.googleauthorPark, Kwangwoo-
dc.contributor.googleauthorKim, Min-Joo-
dc.contributor.googleauthorShin, Han Back-
dc.contributor.googleauthorLee, Se Hyung-
dc.contributor.googleauthorKim, Jin Sung-
dc.identifier.doi10.1002/acm2.12875-
dc.relation.journalcodeJ03009-
dc.identifier.eissn1526-9914-
dc.subject.keywordDICOM-
dc.subject.keywordMVCT-
dc.subject.keywordquality assurance-
dc.subject.keywordradixact-
dc.subject.keywordtomotherapy-
dc.contributor.alternativeNamePark, Kwang Woo-
dc.contributor.affiliatedAuthorHan, Min Cheol-
dc.contributor.affiliatedAuthorHong, Chae-Seon-
dc.contributor.affiliatedAuthorChang, Kyung Hwan-
dc.contributor.affiliatedAuthorKim, Jihun-
dc.contributor.affiliatedAuthorHan, Su Chul-
dc.contributor.affiliatedAuthorKim, Dong Wook-
dc.contributor.affiliatedAuthorPark, Kwangwoo-
dc.contributor.affiliatedAuthorKim, Jin Sung-
dc.identifier.scopusid2-s2.0-85083216284-
dc.identifier.wosid000524903800001-
dc.citation.volume21-
dc.citation.number6-
dc.citation.startPage151-
dc.citation.endPage157-
dc.identifier.bibliographicCitationJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, Vol.21(6) : 151-157, 2020-06-
dc.identifier.rimsid69322-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorDICOM-
dc.subject.keywordAuthorMVCT-
dc.subject.keywordAuthorquality assurance-
dc.subject.keywordAuthorradixact-
dc.subject.keywordAuthortomotherapy-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.