dc.description.abstractPurpose: Cubitus varus is a common triplane deformity in adults associated with supracondylar humeral fractures experienced as a child and consists of varus, extension, and internal rotation components. When corrective osteotomy is indicated, these three components should be measured precisely. This study aimed to evaluate the accuracy of radiographic and physical measurements of cubitus varus deformities in adults compared to values measured on three-dimensional (3-D) bone surface models of the adult bilateral humerus. Methods: Three-dimensional bilateral humerus models were developed using bilateral humerus CT images of 20 adult patients with cubitus varus. The varus, internal rotation, and extension components of the deformity were assessed by superimposing the 3-D bone model onto a mirror-image model of the contralateral normal humerus. Values obtained from the radiographic and physical measurements were compared with those from the 3D model. The reliability of each measurement was assessed by calculating correlation coefficients (CCs). Results: Radiographic measurements of the varus and extension components showed good reliability (CC = 0.796 and 0.791, respectively). Physical measurement of the varus component, however, showed only moderate reliability (CC= 0.539), while physical measurement of the extension and internal rotation components exhibited poor reliability (CC = 0.164 and 0.466, respectively). Conclusion: Varus and extension components of cubitus varus in adults can be reliably measured using conventional methods, whereas the internal rotation component cannot. Thus, 3-D methods with which to quantify the rotational component preoperatively might be needed when the correction of a rotational deformity is considered.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherDove Medical Press-
dc.relation.isPartOfTHERAPEUTICS AND CLINICAL RISK MANAGEMENT-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleAccuracy of Conventional Triplane Measures Compared to 3-D Analysis for Assessment of Cubitus Varus Deformities in Adults-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Orthopedic Surgery (정형외과학교실)-
dc.contributor.googleauthorGil-Sung Yoon-
dc.contributor.googleauthorWon-Taek Oh-
dc.contributor.googleauthorYong-Min Chun-
dc.contributor.googleauthorIl-Hyun Koh-
dc.contributor.googleauthorHo-Jung Kang-
dc.contributor.googleauthorYun-Rak Choi-
dc.identifier.doi10.2147/TCRM.S238142-
dc.contributor.localIdA02391-
dc.contributor.localIdA00141-
dc.contributor.localIdA00098-
dc.contributor.localIdA04028-
dc.contributor.localIdA04136-
dc.relation.journalcodeJ03439-
dc.identifier.eissn1178-203X-
dc.identifier.pmid32431506-
dc.subject.keywordcomputed tomography-
dc.subject.keywordcubitus varus-
dc.subject.keywordpreoperative evaluation-
dc.subject.keywordtriplane measurement-
dc.contributor.alternativeNameOh, Won Taek-
dc.contributor.affiliatedAuthor오원택-
dc.contributor.affiliatedAuthor고일현-
dc.contributor.affiliatedAuthor강호정-
dc.contributor.affiliatedAuthor천용민-
dc.contributor.affiliatedAuthor최윤락-
dc.citation.volume16-
dc.citation.startPage349-
dc.citation.endPage355-
dc.identifier.bibliographicCitationTHERAPEUTICS AND CLINICAL RISK MANAGEMENT, Vol.16 : 349-355, 2020-05-