104 272

Cited 0 times in

Implantable Cardioverter-Defibrillator Lead Extraction by Conventional Traction and Counter-Traction Technique

DC Field Value Language
dc.contributor.author박희남-
dc.contributor.author이문형-
dc.contributor.author정보영-
dc.date.accessioned2020-08-14T03:15:50Z-
dc.date.available2020-08-14T03:15:50Z-
dc.date.issued2010-08-
dc.identifier.issn1738-5520-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/178656-
dc.description.abstractA 46-year-old man presented to our institution with inappropriate implantable cardioverter-defibrillator (ICD) shock delivery. The ICD (single chamber, dual shock coils) was implanted for sustained monomorphic ventricular tachycardia with unstable hemodynamics and underlying systolic left ventricular dysfunction. ICD interrogation revealed recurrent episodes of ICD shock due to noise sensing and increased impedance of right ventricular (RV)-lead. With the impression of lead fracture, ICD lead extraction was performed. The fractured ICD lead was completely removed by traction of locking stylet and countertraction of polypropylene dilator sheath. A new lead was inserted and the patient was discharged without complications after 2 days. To our knowledge, this is the first report on ICD lead extraction by conventional traction and counter-traction technique in Korea.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish, Korean-
dc.publisherKorean Society of Circulation-
dc.relation.isPartOfKorean Circulation Journal-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleImplantable Cardioverter-Defibrillator Lead Extraction by Conventional Traction and Counter-Traction Technique-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorJong Sung Park-
dc.contributor.googleauthorHui-Nam Pak-
dc.contributor.googleauthorMoon-Hyoung Lee-
dc.contributor.googleauthorSung Soon Kim-
dc.contributor.googleauthorBoyoung Joung-
dc.identifier.doi10.4070 / kcj.2010.40.8.418-
dc.contributor.localIdA01776-
dc.contributor.localIdA02766-
dc.contributor.localIdA03609-
dc.relation.journalcodeJ01952-
dc.identifier.eissn1738-5555-
dc.subject.keywordDevice failure-
dc.subject.keywordImplantable cardioverter defibrillator-
dc.subject.keywordDevice removal-
dc.contributor.alternativeNamePak, Hui Nam-
dc.contributor.affiliatedAuthor박희남-
dc.contributor.affiliatedAuthor이문형-
dc.contributor.affiliatedAuthor정보영-
dc.citation.volume40-
dc.citation.number3-
dc.citation.startPage418-
dc.citation.endPage420-
dc.identifier.bibliographicCitationKorean Circulation Journal, Vol.40(3) : 418-420, 2010-08-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.