330 477

Cited 2 times in

Comparison of Analytical Performance of i-Smart 300 and pHOx Ultra for the Accurate Determination of Pleural Fluid pH

DC Field Value Language
dc.contributor.author김영삼-
dc.contributor.author김정호-
dc.contributor.author이상국-
dc.date.accessioned2020-07-09T16:41:06Z-
dc.date.available2020-07-09T16:41:06Z-
dc.date.issued2019-01-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/178104-
dc.description.abstractBackground: Pleural fluid pH is an essential test for diagnosing complicated parapneumonic effusion. We evaluated the performance of two blood gas analyzers in measuring pleural fluid pH. Methods: The i-STAT G3+ (Abbott) was used as a reference analyzer to evaluate the pH values obtained from other methods: the i-Smart 300 (i-SENS), the pHOx Ultra (Nova Biomedical), using a clot catcher to filter off microclot, and pH indicator paper. Within-device precision was performed using quality control materials. We compared pleural fluid pH (n = 86) by the above methods and analyzed the concordance rate at the level of the medical decision point, pH 7.2. Results: The within-device coefficient of variations of pH were below 0.1% for all blood gas analyzers tested. The slopes of the regression equations for the i-Smart 300, pHOx Ultra, and pH indicator paper against the reference analyzer were 0.850 (95% confidence interval, CI, 0.800-0.896), 0.714 (95% CI, 0.671-0.766), and 1.105 (95% CI, 0.781-1.581), respectively. The kappa values for the i-Smart 300, pHOx Ultra, and pH indicator paper against the reference analyzer were 0.883 (95% CI, 0.656-1.110), 0.739 (95% CI, 0.393-1.084), and 0.464 (95% CI, 0.102-0.826), respectively. Conclusions: The i-Smart 300 and pHOx Ultra demonstrated good analytical performance and diagnostic accuracy when determining pleural fluid pH compared with that by the i-STAT G3+, whereas the pH indicator paper showed unsatisfactory results.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherElsevier B.V.-
dc.relation.isPartOfPractical Laboratory Medicine-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleComparison of Analytical Performance of i-Smart 300 and pHOx Ultra for the Accurate Determination of Pleural Fluid pH-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorJooyoung Cho-
dc.contributor.googleauthorYoung Sam Kim-
dc.contributor.googleauthorYoung Hwan Kim-
dc.contributor.googleauthorJae-Yeon Lee-
dc.contributor.googleauthorIn Cheol Bae-
dc.contributor.googleauthorSang-Guk Lee-
dc.contributor.googleauthorJeong-Ho Kim-
dc.identifier.doi10.1016/j.plabm.2019.e00117-
dc.contributor.localIdA00707-
dc.contributor.localIdA00903-
dc.contributor.localIdA02810-
dc.relation.journalcodeJ03550-
dc.identifier.eissn2352-5517-
dc.identifier.pmid30815526-
dc.subject.keywordBlood gas analyzer-
dc.subject.keywordComplicated parapneumonic effusion-
dc.subject.keywordPleural effusion-
dc.subject.keywordPleural fluid pH-
dc.contributor.alternativeNameKim, Young Sam-
dc.contributor.affiliatedAuthor김영삼-
dc.contributor.affiliatedAuthor김정호-
dc.contributor.affiliatedAuthor이상국-
dc.citation.volume14-
dc.citation.startPagee00117-
dc.identifier.bibliographicCitationPractical Laboratory Medicine, Vol.14 : e00117, 2019-01-
dc.identifier.rimsid64424-
dc.type.rimsART-