0 349

Cited 0 times in

리도카인 대사산물인 MEGX(Monoethyl-glycinexylidide)을 이용한 간기능 검사

DC Field Value Language
dc.contributor.author김경식-
dc.date.accessioned2020-07-06T16:59:38Z-
dc.date.available2020-07-06T16:59:38Z-
dc.date.issued1997-
dc.identifier.issn1738-6349-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/178062-
dc.description.abstractThe quantitative assessment of preoperative liver function is essential since hepatic reserve function after hepatic resection has significant influence on the prognosis. But conventional liver function tests are limited in quantitating hepatic function and can only assess the presence or absence of hepatobiliary injury without reflecting the severity of the disease. More recently, measurements of hepatic lidocaine metabolism to its primary metabolite monoethylglycinexylidide(MEGX) taken by an automated fluorescent polarization immunoassay with a TDx analyzer(Abbott Laboratories, Diagnostic Division, North Chicago, IL) have demonstrated a means for a rapid and reproducible assessment of hepatic function. Therefore, to determine the clinical value of this lidocaine metabolite as a quantitative liver function test, we measured the serum MEGX concentration, 15 min after intravenous administration of single dose of lidocaine 1㎎/㎏) in 40 adults. The following side effects were recorded : dizziness(N=39), tinnitus(N=39), perioral numbness(N=3), and febrile sensation(N=1). These side effects were mild, disappearing within 5 minutes. 6 of 40 cases were excluded due to abnormal liver function and/or very low MEGX concentrations(less than 10 percentile). The peak MEGX concentration of 34 cases, 15 min after injection of lidocaine, was 431.8±14.74ng/㎖(men S.E) with the reference value between from 35.47 and 51.80 ng/㎖(25-75 percentile). The measurement of MEGX concentration, 15 min after lidocaine injection, may serve as a simple, safe, and rapid quantitative liver function test, but further prospective studies in cases with chronic hepatitis and primary hepatoma are needed in order to establish the cutoff level of MEGX concentration that can determine the abnormality.-
dc.description.statementOfResponsibilityrestriction-
dc.languageKorean Journal of Hepato-Biliary-Pancreatic Surgery-
dc.publisherKorean Journal of Hepato-Biliary-Pancreatic Surgery-
dc.relation.isPartOfKorean Journal of Hepato-Biliary-Pancreatic Surgery-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title리도카인 대사산물인 MEGX(Monoethyl-glycinexylidide)을 이용한 간기능 검사-
dc.title.alternativeHepatic Function Index using lidocaine metabolite-MonoEthylGlycineXylidide(MEGX)-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Surgery (외과학교실)-
dc.contributor.googleauthor김경식-
dc.contributor.googleauthor이우정-
dc.contributor.googleauthor최진섭-
dc.contributor.googleauthor김병로-
dc.contributor.googleauthor이정운-
dc.contributor.localIdA00299-
dc.relation.journalcodeJ02035-
dc.identifier.eissn2288-9213-
dc.identifier.urlhttp://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01985008-
dc.contributor.alternativeNameKim, Kyung Sik-
dc.contributor.affiliatedAuthor김경식-
dc.citation.volume1-
dc.citation.number1-
dc.citation.startPage39-
dc.citation.endPage47-
dc.identifier.bibliographicCitationKorean Journal of Hepato-Biliary-Pancreatic Surgery, Vol.1(1) : 39-47, 1997-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.