321 288

Cited 0 times in

폐정맥 혈류와 승모판 혈류를 이용한 비침습적 좌심실 확장기압 측정

DC Field Value Language
dc.contributor.author권혁문-
dc.contributor.author심원흠-
dc.contributor.author임세중-
dc.contributor.author장양수-
dc.contributor.author정남식-
dc.contributor.author하종원-
dc.date.accessioned2020-07-03T18:04:47Z-
dc.date.available2020-07-03T18:04:47Z-
dc.date.issued1997-
dc.identifier.issn1738-5520-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/177987-
dc.description.abstractBackground Doppler variable of mitral inflow have been used to assess left ventricular siastolic function indirectly. Pulmonary venous flow(PVF) variables could supplement mitral inflow in the estimation of left ventricular diastolic function. The purpose of this study are to assess the feasibility of PVF measurement by using transthoracic pulsed wave Doppler echocardiogram and to estimate the LV end-diastolic pressure with PVF parameters. Methods Fifty six patients underwent transthoracic pulsed wave Doppler echocardiagraphy (HP Sonos 1500) within 2 hours before left heart catheterization for the measurement of left ventricular pressure. Results 1) Measurement of transthoracic PVF was feasible in 50 patients(89.3%). 2) The difference between the duration of pulmonary venous reversal flow and mitral A wave(D difference, delta D) was strongly correlated with left ventricular end diastolic pressure(r=0.73, p<0.01). PVF reversal duration exceeding that of mitral A wave predicted left ventricular end diastolic pressure ≥12mmHg(sensitivity 90.6%, specificity 50.0%). Conclusion PVF could be assessed with transthoracic Doppler ultrasound with good feasibility. PVF may be an important parameter in the evaluation of left ventricular diastolic function. PVF reveral duration exceeding that of mitral A wave would be a marker of elevated left ventricular end diastolic pressure(≥12mmHg). Plumonary venous flow . Transmitral inflow . Left ventricular end diastolic pressure. Transthorasic doppler echocardiography.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한심장학회-
dc.relation.isPartOfKorean Circulation Journal (순환기)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title폐정맥 혈류와 승모판 혈류를 이용한 비침습적 좌심실 확장기압 측정-
dc.title.alternativeAssessment of Left Ventricular Diastolic Pressures with Pulmonary Venous Flow and Transmitral Inflow by Doppler Echocardiography Echocardiography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthor김동수-
dc.contributor.googleauthor정남식-
dc.contributor.googleauthor임세중-
dc.contributor.googleauthor권준-
dc.contributor.googleauthor권혁문-
dc.contributor.googleauthor김현승-
dc.contributor.googleauthor박현영-
dc.contributor.googleauthor김지영-
dc.contributor.googleauthor하종원-
dc.contributor.googleauthor장양수-
dc.contributor.googleauthor심원흠-
dc.contributor.googleauthor조승연-
dc.contributor.googleauthor김성순-
dc.identifier.doi10.4070/kcj.1997.27.3.312-
dc.contributor.localIdA00260-
dc.contributor.localIdA02202-
dc.contributor.localIdA03372-
dc.contributor.localIdA03448-
dc.contributor.localIdA03585-
dc.contributor.localIdA04257-
dc.relation.journalcodeJ01953-
dc.identifier.eissn1738-5555-
dc.contributor.alternativeNameKwon, Hyuck Moon-
dc.contributor.affiliatedAuthor권혁문-
dc.contributor.affiliatedAuthor심원흠-
dc.contributor.affiliatedAuthor임세중-
dc.contributor.affiliatedAuthor장양수-
dc.contributor.affiliatedAuthor정남식-
dc.contributor.affiliatedAuthor하종원-
dc.citation.volume27-
dc.citation.number3-
dc.citation.startPage312-
dc.citation.endPage317-
dc.identifier.bibliographicCitationKorean Circulation Journal (순환기), Vol.27(3) : 312-317, 1997-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.