196 300

Cited 0 times in

체외순환후 좌심실내 공기방울의 제거속도에 영향을 미치는 인자들

DC Field Value Language
dc.contributor.author곽영란-
dc.date.accessioned2020-07-03T17:27:48Z-
dc.date.available2020-07-03T17:27:48Z-
dc.date.issued1997-
dc.identifier.issn0302-5780-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/177571-
dc.description.abstractBACKGROUND Air trapped in left ventricle(LV) after cardiopulmonary bypass(CPB) is a major source of air embolism. We tried to measure the length of time(T) to remove the air bubbles from release of aortic cross clamp(ACC) and to find the factors affecting the length of time. METHODS With Institutional Review Board(IRB) approval, 125 patients undergoing valvular replacement and repair of atrial septal defect(ASD) were included in this prospective study. After induction of anesthesia, a 5-MHz phased-array transesophageal echocardiographic(TEE) probe was inserted into the esophagus and then connected to the TEE system. TEE was continuously monitored from the time of release ACC to the end of operation. And the length of time from release of ACC to disappearance of the air bubbles in LV was recorded. RESULTS The mean T was 27.5+/-12.0 minutes and was statistically longer in patients undergoing mitral valve replacement than in patients with ASD. There was significant difference in T between surgeon 1 and surgen 2. In patients with atrial fibrillation(A-fib) the air bubbles were removed more slowly than in patients with normal sinus rhythm preoperatively and there was negative correlation between preoperative ejection fraction(EF) and the length of time to remove air bubbles(r= 0.23). CONCLUSIONS Careful management to remove the air bubbles from the LV after release of ACC is required in patients with low EF or A-fib preoperatively and surgeon's attention is required because they are the important factor affecting the length of time to remove the air bubble.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한마취과학회-
dc.relation.isPartOfJournal of Korean Society of Anesthesiologist (대한마취과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title체외순환후 좌심실내 공기방울의 제거속도에 영향을 미치는 인자들-
dc.title.alternativeFactors Affecting the Length of Time to Remove the Air Bubble in Left Ventricle Detected by Echocardiography after Cardiopulmonary Bypass-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology and Pain Medicine (마취통증의학교실)-
dc.contributor.googleauthor곽영란-
dc.contributor.googleauthor홍용우-
dc.contributor.googleauthor유은숙-
dc.contributor.googleauthor방서욱-
dc.contributor.googleauthor이춘수-
dc.contributor.googleauthor강상화-
dc.contributor.googleauthor김명옥-
dc.identifier.doi10.4097/kjae.1997.32.4.574-
dc.contributor.localIdA00172-
dc.relation.journalcodeJ01540-
dc.subject.keywordEmbolism-
dc.subject.keywordair-
dc.subject.keywordMonitoring-
dc.subject.keywordtransesophageal echocardiography-
dc.subject.keywordSurgery-
dc.subject.keywordcardiac-
dc.contributor.alternativeNameKwak, Young Lan-
dc.contributor.affiliatedAuthor곽영란-
dc.citation.volume32-
dc.citation.number4-
dc.citation.startPage574-
dc.citation.endPage580-
dc.identifier.bibliographicCitationJournal of Korean Society of Anesthesiologist (대한마취과학회지), Vol.32(4) : 574-580, 1997-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.