dc.description.abstractBACKGROUND It has been known that pressure gradient(PG) between systolic radial arterial pressure(RAP) and systolic aortic pressure(AP) is often altered after cardiopulmonary bypass(CPB). In this study, we compared radial to femoral arterial pressure(FAP) difference between valve replacement(VR) group(n=189) and coronary artery bypass graft (CABG) group(n=90). METHODS With IRB approval, anesthesia management followed the standard method for cardiac surgery. Heart rate, RAP, FAP, cardiac index(CI), forearm skin temperature, hematocirt and systemic vascular resistance index(SVRI) were recorded at before-CPB, after-CPB and after sternal closure. RESULTS In CABG group, there was no change of PG between RAP and FAP before and after CPB. In VR group, systolic RAP was similar with FAP before CPB but the radial-femoral arterial pressure gradient was reversed with statistical significance after bypass. Compare with CAGB group, change of pressure gradient after CPB cousiderded statistical significant in valve replacement group. CI was increased and SVRI was decreased with statistical significance. CONCLUSION In our study, patients in VR group who demonstrated high CI and low SVRI showed reversal of PG upon cessation of CPB. Reversal of PG at post-CPB probably partially depends on the degree of systemic vasodilation upon discontinuation of CPB.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한마취과학회-
dc.relation.isPartOfJournal of Korean Society of Anesthesiologist (대한마취과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title관상동맥 우회술 및 판막대치술환자에서 체외순환 전후의 대퇴요골동맥압간의 차이의 변화 비교-
dc.title.alternativeComparison of Femoral to Radial Artery Pressure during Coronary Artery bypass Graft and Valvular Surgery-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology and Pain Medicine (마취통증의학교실)-
dc.contributor.googleauthor곽영란-
dc.contributor.googleauthor홍용우-
dc.contributor.googleauthor방서욱-
dc.contributor.googleauthor유은숙-
dc.contributor.googleauthor장정화-
dc.contributor.googleauthor한승연-
dc.contributor.googleauthor임현경-
dc.identifier.doi10.4097/kjae.1997.32.2.260-
dc.contributor.localIdA00172-
dc.relation.journalcodeJ01540-
dc.subject.keywordMonitoring blood pressure-
dc.subject.keywordSurgery coronary artery bypass graft valvular replacement-
dc.contributor.alternativeNameKwak, Young Lan-
dc.contributor.affiliatedAuthor곽영란-
dc.citation.volume32-
dc.citation.number2-
dc.citation.startPage260-
dc.citation.endPage266-
dc.identifier.bibliographicCitationJournal of Korean Society of Anesthesiologist (대한마취과학회지), Vol.32(2) : 260-266, 1997-