165 274

Cited 0 times in

지속적 저용량 인슐린/포도당 주입검사(LDIGIT,Low Dose Insulin and Glucose Infusion Test)를 이용한 인슐린 감수성의 측정

DC Field Value Language
dc.contributor.author이현철-
dc.date.accessioned2020-07-02T16:58:06Z-
dc.date.available2020-07-02T16:58:06Z-
dc.date.issued1998-
dc.identifier.issn1015-6461-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/176489-
dc.description.abstractBACKGROUND: Measurement of insulin sensitivity index by continuous low dose insulin and glucose infusion test(LDIGIT) has been reported to be simple and reliable. METHODS: The method is a refinement of the modified Harano test and consisted of continuous low dose insulin(25mU/kghr) and glucose(4mg/kghr) infusion lasting 150 min. Insulin sensitivity was evaluated as the amount of glucose infusion divided by the steady state serum insulin and glucose levels achieved at the end of the test. Insulin secretion was expressed as the incremental area for C-peptide concentration during the first 15 min of the test. The indices of insulin sensitivity and insulin secretion yielded by LDIGIT were compared with those derived from the euglycemic clamp and oral glucose tolerance test (OGTT), respectively. Thirteen subjects underwent LDIGIT and euglycemic clamp. RESULTS: LDIGIT resulted in stable final glucose levels but 3 subjects showed hypoglycemia during the test. The index of insulin secretion provided by LBIGIT did not correlate well with that of OGTT. There was a significant correlation between the ISI (insulin sensitivity index) determined by LDIGIT and the ISI determined by clamp(r=0.60, p<0.05). CONCLUSION: LDIGIT is a simple and accurate methcd to assess insulin sensitivity. It can be used in population studies and in situations when more complex technique is not feasible. However, it is desirable to reduce the insulin infusion rate to avoid the occurrence of hypoglycemia in Koreans.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한당뇨병학회-
dc.relation.isPartOfJournal of Korean Diabetes Association (당뇨병)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title지속적 저용량 인슐린/포도당 주입검사(LDIGIT,Low Dose Insulin and Glucose Infusion Test)를 이용한 인슐린 감수성의 측정-
dc.title.alternativeMeasurement of Insulin Sensitivity Index Estimated from LDIGIT(Continuous Low Dose Insulin and Glucose Infusion Test)-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthor송영득-
dc.contributor.googleauthor차봉수-
dc.contributor.googleauthor박석원-
dc.contributor.googleauthor워영준-
dc.contributor.googleauthor남수연-
dc.contributor.googleauthor임승길-
dc.contributor.googleauthor김경래-
dc.contributor.localIdA03301-
dc.relation.journalcodeJ01508-
dc.contributor.alternativeNameLee, Hyun Chul-
dc.contributor.affiliatedAuthor이현철-
dc.citation.volume21-
dc.citation.number4-
dc.citation.startPage425-
dc.citation.endPage432-
dc.identifier.bibliographicCitationJournal of Korean Diabetes Association (당뇨병), Vol.21(4) : 425-432, 1998-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.