431 412

Cited 10 times in

A Portable Smartphone-linked Device for Direct, Rapid and Chemical-Free Hemoglobin Assay

DC Field Value Language
dc.contributor.author송재우-
dc.date.accessioned2020-06-17T00:57:16Z-
dc.date.available2020-06-17T00:57:16Z-
dc.date.issued2020-05-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/176195-
dc.description.abstractWe describe the development and clinical evaluation of an automated smartphone-linked sensor capable of chemical-free, quantitative measurement of hemoglobin concentration ([Hb]) in whole blood samples. We have demonstrated that our sensor could analyze an unprocessed blood specimen with a mean processing time of <8 s and provided the [Hb] results with ~99% accuracy against a reference hematology analyzer with coefficient of variation (CV) of 1.21% measured at [Hb] = 11.2 g/dL. Its diagnostic capability for anemia was evaluated by measuring [Hb] of 142 clinical blood specimens and comparing the results with those from an automated hematology analyzer (ADVIA 2120i, Siemens AG, Germany) and a portable hemoglobinomteter (Hb201+, Hemocue, Sweden). The sensor yielded comparable sensitivities and specificities of 87.50% and 100.00% for males, and 94.44% and 100.00% for females, respectively, for anemic detection. The results suggested that our optical sensor based on the intrinsic photothermal response of Hb molecules and advances in consumer electronics, particularly smartphone capabilities, enables a direct, chemical-free [Hb] assay accessible to people in both developed and developing countries.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherNature Publishing Group-
dc.relation.isPartOfSCIENTIFIC REPORTS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleA Portable Smartphone-linked Device for Direct, Rapid and Chemical-Free Hemoglobin Assay-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorJunho Lee-
dc.contributor.googleauthorJaewoo Song-
dc.contributor.googleauthorJun-Ho Choi-
dc.contributor.googleauthorSoocheol Kim-
dc.contributor.googleauthorUihan Kim-
dc.contributor.googleauthorVan-Thuan Nguyen-
dc.contributor.googleauthorJong-Seok Lee-
dc.contributor.googleauthorChulmin Joo-
dc.identifier.doi10.1038/s41598-020-65607-8-
dc.contributor.localIdA02054-
dc.relation.journalcodeJ02646-
dc.identifier.eissn2045-2322-
dc.identifier.pmid32451400-
dc.contributor.alternativeNameSong, Jae Woo-
dc.contributor.affiliatedAuthor송재우-
dc.citation.volume10-
dc.citation.number1-
dc.citation.startPage8606-
dc.identifier.bibliographicCitationSCIENTIFIC REPORTS, Vol.10(1) : 8606, 2020-05-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode