dc.description.abstractThis case report presents the cases of single anterior missing and posterior free-end edentulous ridge with computer-guided implant placement on the day of visit through a special tray containing fiducial markers without model scan or intraoral scan data. Cone beam CT was taken after fixing the marker embedded ready-made tray with a photopolymerized resin material by light-curing in the patient's mouth. The implant location was planned on the registered CT data in the planning software. The tool path calculation for the milling machine was conducted in the computer-aided manufacture (CAM) software. The guide was completed by milling the drill hole in the special tray as designed. Although the preparation for the conventional implant guide surgery takes considerable time, including data acquisition and 3D printing, it was possible to produce a guide on the day of the patient visit without a separate procedure other than a CT scan through this protocol. Also, the transfer of the implant surgery plan, the process of scanning and 3D printing, was omitted, thereby reducing the positional error between the CT data and the actual guide.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageImplantology-
dc.publisherImplantology-
dc.relation.isPartOfImplantology-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title부분무치악에서 모델프리, 제로셋업 컴퓨터-가이드 임플란트 수술용 템플릿의 활용 증례-
dc.title.alternativeUse of Model-Free and Zero-Setup Computer-Guided Implant Surgical Template for Partial Edentulous Cases-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학교실)-
dc.contributor.googleauthor허봉천-
dc.contributor.googleauthor오경철-
dc.contributor.googleauthor심준성-
dc.contributor.googleauthor박지만-
dc.identifier.doi10.32542/implantology.2019019-
dc.contributor.localIdA05595-
dc.contributor.localIdA02211-
dc.contributor.localIdA04976-
dc.relation.journalcodeJ03149-
dc.contributor.alternativeNamePark, Ji-Man-
dc.contributor.affiliatedAuthor박지만-
dc.contributor.affiliatedAuthor심준성-
dc.contributor.affiliatedAuthor오경철-
dc.citation.volume23-
dc.citation.number4-
dc.citation.startPage220-
dc.citation.endPage228-
dc.identifier.bibliographicCitationImplantology, Vol.23(4) : 220-228, 2019-12-
dc.identifier.rimsid64884-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.