Cited 19 times in

Accuracy of Scanned Stock Abutments Using Different Intraoral Scanners: An In Vitro Study

DC Field Value Language
dc.contributor.author김종은-
dc.contributor.author김지환-
dc.contributor.author심준성-
dc.date.accessioned2020-06-04T08:45:03Z-
dc.date.available2020-06-04T08:45:03Z-
dc.date.issued2019-08-
dc.identifier.issn1059-941X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/175865-
dc.description.abstractPurpose: To determine the accuracy of a digital manufacturing method for dental implant restorations on stock abutments using intraoral scanners and prefabricated stock-abutment libraries. Materials and methods: Two dental implants with internal hexagonal connections were placed in the mandibular second premolar and second molar areas of a partially edentulous dentoform model; stock abutments with a diameter of 5 mm, abutment height of 5.5 mm, and gingival cuff height of 2 mm were connected. The study model was scanned 10 times using a reference tabletop scanner and 5 types of intraoral scanners (IOSs). The data collected by 5 types of IOSs were divided into 3 groups, based on the type and matching of stock abutment library data: no library, optical library, and contact library groups. A total of 160 data files were analyzed, including reference data. The resulting data were used to evaluate trueness and precision. Results: Trueness and precision values in the group in which library data of the stock abutment were not used were 42.0 to 76.3 µm and 30.5 to 99.7 µm; corresponding values when the library data using an optical scanner were matched were 51.2 to 73.4 µm and 26.3 to 62.8 µm, and those when contact scanner library data were used were 30.1 to 62.4 µm and 15.5 to 55.9 µm. Thus, the accuracy of the contact library group was significantly higher than the accuracies of the no library (p < 0.001) and optical library groups (p < 0.001). Conclusion: The application of prefabricated library data of stock abutments using a contact scanner improved the accuracy of scan data. Scan accuracy of the stock abutments differed significantly based on the type of scanner.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherWiley-Blackwell-
dc.relation.isPartOfJOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHComputer-Aided Design-
dc.subject.MESHDental Abutments-
dc.subject.MESHDental Implants*-
dc.subject.MESHDental Impression Technique-
dc.subject.MESHHumans-
dc.subject.MESHMouth, Edentulous*-
dc.titleAccuracy of Scanned Stock Abutments Using Different Intraoral Scanners: An In Vitro Study-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학교실)-
dc.contributor.googleauthorJong-Eun Kim-
dc.contributor.googleauthorYoung-Sun Hong-
dc.contributor.googleauthorYou-Jung Kang-
dc.contributor.googleauthorJee-Hwan Kim-
dc.contributor.googleauthorJune-Sung Shim-
dc.identifier.doi10.1111/jopr.13095-
dc.contributor.localIdA00927-
dc.contributor.localIdA01006-
dc.contributor.localIdA02211-
dc.relation.journalcodeJ01719-
dc.identifier.eissn1532-849X-
dc.identifier.pmid31250506-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/full/10.1111/jopr.13095-
dc.subject.keywordIntraoral scanning-
dc.subject.keywordprecision-
dc.subject.keywordstock abutments-
dc.subject.keywordtrueness-
dc.contributor.alternativeNameKim, Jong Eun-
dc.contributor.affiliatedAuthor김종은-
dc.contributor.affiliatedAuthor김지환-
dc.contributor.affiliatedAuthor심준성-
dc.citation.volume28-
dc.citation.number7-
dc.citation.startPage797-
dc.citation.endPage803-
dc.identifier.bibliographicCitationJOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, Vol.28(7) : 797-803, 2019-08-
dc.identifier.rimsid64760-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.