Cited 16 times in

Utility of FDG PET/CT for Preoperative Staging of Non-Small Cell Lung Cancers Manifesting as Subsolid Nodules With a Solid Portion of 3 cm or Smaller

Authors
 Young Joo Suh  ;  Chang Min Park  ;  Kyunghwa Han  ;  Sun Kyung Jeon  ;  Hyungjin Kim  ;  Eui Jin Hwang  ;  Jong Hyuk Lee  ;  Jin Chul Paeng  ;  Chang Hoon Lee  ;  Young Tae Kim  ;  Jin Mo Goo 
Citation
 AMERICAN JOURNAL OF ROENTGENOLOGY, Vol.214(3) : 514-523, 2020 
Journal Title
AMERICAN JOURNAL OF ROENTGENOLOGY
ISSN
 0361-803X 
Issue Date
2020
Keywords
CT ; PET ; cancer staging ; non–small cell lung cancer ; subsolid nodule
Abstract
OBJECTIVE. The objective of our study was to investigate the utility of FDG PET/CT for the preoperative staging of subsolid non-small cell lung cancers (NSCLCs) with a solid portion size of 3 cm or smaller. MATERIALS AND METHODS. We retrospectively enrolled 855 patients with pathologically proven NSCLCs manifesting as subsolid nodules with a solid portion of 3 cm or smaller on CT. We then compared the diagnostic performances of FDG PET/CT and chest CT for detecting lymph node (LN), intrathoracic, or distant metastases in patients who underwent preoperative chest CT and FDG PET/CT. After propensity score matching, we compared the diagnostic performance of FDG PET/CT in the group who underwent both chest CT and FDG PET/CT with that of chest CT in patients who did not undergo FDG PET/CT. RESULTS. There were LN metastases in 25 of 765 patients (3.3%) who underwent surgical LN dissection or biopsy and intrathoracic or distant metastasis in two of 855 patients (0.2%). For LN staging, FDG PET/CT showed a sensitivity of 44.0%, specificity of 81.5%, positive predictive value of 9.6%, negative predictive value of 97.0%, and accuracy of 79.9%, which were lower than those of chest CT for accuracy (p < 0.0001). FDG PET/CT could not accurately detect any intrathoracic or distant metastasis. After propensity score matching, the diagnostic accuracy for LN staging of FDG PET/CT in the group who underwent both CT and FDG PET/CT was lower than that of chest CT in the group who did not undergo FDG PET/CT (p = 0.002), and the diagnostic accuracy for intrathoracic and distant metastases was not different (p > 0.999). CONCLUSION. FDG PET/CT has limited utility in preoperatively detecting LN or distant metastasis in patients with subsolid NSCLCs with a solid portion size of 3 cm or smaller.
Full Text
https://www.ajronline.org/doi/full/10.2214/AJR.19.21811
DOI
10.2214/AJR.19.21811
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Suh, Young Joo(서영주) ORCID logo https://orcid.org/0000-0002-2078-5832
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/175610
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links