0 703

Cited 5 times in

Cited 9 times in

Optical Coherence Tomography for Coronary Bioresorbable Vascular Scaffold Implantation A Randomized Controlled Trial

DC Field Value Language
dc.contributor.authorLee, Seung-Yul-
dc.contributor.authorKang, Do-Yoon-
dc.contributor.authorHong, Sung-Jin-
dc.contributor.authorAhn, Jung-Min-
dc.contributor.authorAhn, Chul-Min-
dc.contributor.authorPark, Duk-Woo-
dc.contributor.authorKim, Jung-Sun-
dc.contributor.authorKim, Byeong-Keuk-
dc.contributor.authorKo, Young-Guk-
dc.contributor.authorChoi, Donghoon-
dc.contributor.authorJang, Yangsoo-
dc.contributor.authorPark, Seung-Jung-
dc.contributor.authorHong, Myeong-Ki-
dc.date.accessioned2020-04-13T16:44:35Z-
dc.date.available2020-04-13T16:44:35Z-
dc.date.created2021-03-17-
dc.date.issued2020-01-
dc.identifier.issn1941-7640-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/175490-
dc.description.abstractBackground: We investigated whether optical coherence tomography (OCT) guidance would reduce nonoptimal bioresorbable vascular scaffold (BVS) deployment. Methods: This was a randomized controlled trial. Patients who required percutaneous coronary intervention for ischemic heart disease were recruited from 2 centers in Korea. The enrolled patients were randomly assigned to receive either OCT-guided BVS (Absorb; Abbott Vascular) implantation or angiography-guided BVS implantation using an optimized technique. The primary outcome was nonoptimal deployment, which was a composite outcome of the following parameters assessed by OCT: a minimal scaffold area <5 mm(2), residual area stenosis >20%, incomplete apposition of the scaffold struts >5%, major edge dissection, or scaffold disruption. The secondary outcome was a procedural complication defined by the occurrence of no reflow, coronary perforation, or flow-limiting dissection. Results: Between September 2016 and January 2018, 88 patients (90 lesions) were assigned to OCT guidance, while 88 patients (89 lesions) were assigned to angiography guidance. The recruitment was prematurely terminated in March 2018 because the manufacturer stopped supplying BVS. Postprocedural OCT data were available for 88 lesions with OCT guidance and for 88 lesions with angiography guidance. There was nonoptimal BVS deployment postprocedurally in 35.2% of patients in the OCT-guidance group and in 38.6% in the angiography-guidance group (absolute difference, -3.7% [95% CI, -19.0% to 11.6%]; P=0.64). There were no procedural complications in either group. Conclusions: OCT-guided BVS implantation did not reduce the incidence of nonoptimal deployment compared to that of angiography-guided BVS implantation (using optimized techniques).-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherLippincott Williams & Wilkins-
dc.relation.isPartOfCIRCULATION-CARDIOVASCULAR INTERVENTIONS-
dc.relation.isPartOfCIRCULATION-CARDIOVASCULAR INTERVENTIONS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subjectELUTING METALLIC STENT-
dc.subjectCOHORT B TRIAL-
dc.subjectABSORB II-
dc.subjectOUTCOMES-
dc.subjectTHROMBOSIS-
dc.subjectDEPLOYMENT-
dc.titleOptical Coherence Tomography for Coronary Bioresorbable Vascular Scaffold Implantation A Randomized Controlled Trial-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorLee, Seung-Yul-
dc.contributor.googleauthorKang, Do-Yoon-
dc.contributor.googleauthorHong, Sung-Jin-
dc.contributor.googleauthorAhn, Jung-Min-
dc.contributor.googleauthorAhn, Chul-Min-
dc.contributor.googleauthorPark, Duk-Woo-
dc.contributor.googleauthorKim, Jung-Sun-
dc.contributor.googleauthorKim, Byeong-Keuk-
dc.contributor.googleauthorKo, Young-Guk-
dc.contributor.googleauthorChoi, Donghoon-
dc.contributor.googleauthorJang, Yangsoo-
dc.contributor.googleauthorPark, Seung-Jung-
dc.contributor.googleauthorHong, Myeong-Ki-
dc.identifier.doi10.1161/CIRCINTERVENTIONS.119.008383-
dc.relation.journalcodeJ00539-
dc.identifier.eissn1941-7632-
dc.subject.keywordcoronary artery disease-
dc.subject.keywordpercutaneous coronary intervention-
dc.subject.keywordstents-
dc.subject.keywordtomography-
dc.contributor.alternativeNameKo, Young Guk-
dc.contributor.affiliatedAuthorHong, Sung-Jin-
dc.contributor.affiliatedAuthorAhn, Chul-Min-
dc.contributor.affiliatedAuthorKim, Jung-Sun-
dc.contributor.affiliatedAuthorKim, Byeong-Keuk-
dc.contributor.affiliatedAuthorKo, Young-Guk-
dc.contributor.affiliatedAuthorChoi, Donghoon-
dc.contributor.affiliatedAuthorJang, Yangsoo-
dc.contributor.affiliatedAuthorHong, Myeong-Ki-
dc.identifier.scopusid2-s2.0-85083574816-
dc.identifier.wosid000508374800008-
dc.citation.volume13-
dc.citation.number1-
dc.identifier.bibliographicCitationCIRCULATION-CARDIOVASCULAR INTERVENTIONS, Vol.13(1), 2020-01-
dc.identifier.rimsid67878-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorcoronary artery disease-
dc.subject.keywordAuthorpercutaneous coronary intervention-
dc.subject.keywordAuthorstents-
dc.subject.keywordAuthortomography-
dc.subject.keywordPlusELUTING METALLIC STENT-
dc.subject.keywordPlusCOHORT B TRIAL-
dc.subject.keywordPlusABSORB II-
dc.subject.keywordPlusOUTCOMES-
dc.subject.keywordPlusTHROMBOSIS-
dc.subject.keywordPlusDEPLOYMENT-
dc.type.docTypeArticle-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.identifier.articlenoe008383-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.