0 526

Cited 6 times in

Comparing the feasibility and accuracy of three-dimensional ultrasound to two-dimensional ultrasound and computed tomography angiography in the assessment of carotid atherosclerosis

DC Field Value Language
dc.contributor.author송신정-
dc.contributor.author이상은-
dc.contributor.author장혁재-
dc.contributor.author조인정-
dc.contributor.author허란-
dc.date.accessioned2020-02-26T06:37:37Z-
dc.date.available2020-02-26T06:37:37Z-
dc.date.issued2019-
dc.identifier.issn0742-2822-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/175228-
dc.description.abstractAIMS: Two-dimensional ultrasound (2D-US) is the mainstay imaging technique used to evaluate carotid atherosclerosis. An automated single sweep three-dimensional ultrasound (3D-US) technique became available. We evaluated the feasibility and accuracy of 3D-US in the assessment of carotid plaques compared to those of 2D-US. Carotid computed tomography angiography (CTA) was used as a reference. METHODS AND RESULTS: Among 126 stroke patients who underwent carotid 2D-US, 73 underwent 3D-US and carotid CTA. 3D-US was pursued when there were carotid plaques or when area stenosis was ≥ 20% by 2D-US. Both 2D- and 3D-US images of the carotid arteries were acquired using a dedicated ultrasound system that was equipped with the single sweep volumetric transducer. In total, 266 arteries from 73 patients were selected for comparison of the detection rate of carotid plaques between 2D- and 3D-US. Among the 73 patients, carotid CTA detected 139 plaques. 3D-US demonstrated a higher detection rate of carotid plaques than did 2D-US (108 plaques (77.9%) vs. 70 plaques (50.4%)) when using carotid CTA as a reference standard. Carotid plaque volume (PV) of 133 vessels from 73 patients were quantitatively evaluated using both 3D-US and carotid CTA. Plaque volume of carotid artery was comparable between 3D-US and CTA (148.5 ± 133.0 mm3 vs. 154.1 ± 134.6 mm3 , P = .998, R: 0.9825, P-value for r < .001). CONCLUSION: 3D-US using a single sweep technique was a feasible and accurate method of detecting arterial plaques and assessing plaque volume.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherWiley-Blackwell-
dc.relation.isPartOfECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleComparing the feasibility and accuracy of three-dimensional ultrasound to two-dimensional ultrasound and computed tomography angiography in the assessment of carotid atherosclerosis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorShinjeong Song-
dc.contributor.googleauthorRan Heo-
dc.contributor.googleauthorSang‐Eun Lee-
dc.contributor.googleauthorJinki Park-
dc.contributor.googleauthorJinyong Lee-
dc.contributor.googleauthorSujin Kim-
dc.contributor.googleauthorIn Jeong Cho-
dc.contributor.googleauthorHyuk‐Jae Chang-
dc.identifier.doi10.1111/echo.14543-
dc.contributor.localIdA04964-
dc.contributor.localIdA02827-
dc.contributor.localIdA03490-
dc.contributor.localIdA03892-
dc.contributor.localIdA04348-
dc.relation.journalcodeJ00756-
dc.identifier.eissn1540-8175-
dc.identifier.pmid31742790-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/full/10.1111/echo.14543-
dc.subject.keywordatherosclerosis-
dc.subject.keywordcarotid artery-
dc.subject.keywordplaque volume-
dc.subject.keywordthree-dimensional echocardiography-
dc.contributor.alternativeNameSong, Shin Jeong-
dc.contributor.affiliatedAuthor송신정-
dc.contributor.affiliatedAuthor이상은-
dc.contributor.affiliatedAuthor장혁재-
dc.contributor.affiliatedAuthor조인정-
dc.contributor.affiliatedAuthor허란-
dc.citation.volume36-
dc.citation.number12-
dc.citation.startPage2241-
dc.citation.endPage2250-
dc.identifier.bibliographicCitationECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, Vol.36(12) : 2241-2250, 2019-
dc.identifier.rimsid63536-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.