0 480

Cited 6 times in

Comparing the feasibility and accuracy of three-dimensional ultrasound to two-dimensional ultrasound and computed tomography angiography in the assessment of carotid atherosclerosis

Authors
 Shinjeong Song  ;  Ran Heo  ;  Sang‐Eun Lee  ;  Jinki Park  ;  Jinyong Lee  ;  Sujin Kim  ;  In Jeong Cho  ;  Hyuk‐Jae Chang 
Citation
 ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, Vol.36(12) : 2241-2250, 2019 
Journal Title
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES
ISSN
 0742-2822 
Issue Date
2019
Keywords
atherosclerosis ; carotid artery ; plaque volume ; three-dimensional echocardiography
Abstract
AIMS:

Two-dimensional ultrasound (2D-US) is the mainstay imaging technique used to evaluate carotid atherosclerosis. An automated single sweep three-dimensional ultrasound (3D-US) technique became available. We evaluated the feasibility and accuracy of 3D-US in the assessment of carotid plaques compared to those of 2D-US. Carotid computed tomography angiography (CTA) was used as a reference.

METHODS AND RESULTS:

Among 126 stroke patients who underwent carotid 2D-US, 73 underwent 3D-US and carotid CTA. 3D-US was pursued when there were carotid plaques or when area stenosis was ≥ 20% by 2D-US. Both 2D- and 3D-US images of the carotid arteries were acquired using a dedicated ultrasound system that was equipped with the single sweep volumetric transducer. In total, 266 arteries from 73 patients were selected for comparison of the detection rate of carotid plaques between 2D- and 3D-US. Among the 73 patients, carotid CTA detected 139 plaques. 3D-US demonstrated a higher detection rate of carotid plaques than did 2D-US (108 plaques (77.9%) vs. 70 plaques (50.4%)) when using carotid CTA as a reference standard. Carotid plaque volume (PV) of 133 vessels from 73 patients were quantitatively evaluated using both 3D-US and carotid CTA. Plaque volume of carotid artery was comparable between 3D-US and CTA (148.5 ± 133.0 mm3 vs. 154.1 ± 134.6 mm3 , P = .998, R: 0.9825, P-value for r < .001).

CONCLUSION:

3D-US using a single sweep technique was a feasible and accurate method of detecting arterial plaques and assessing plaque volume.
Full Text
https://onlinelibrary.wiley.com/doi/full/10.1111/echo.14543
DOI
10.1111/echo.14543
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Song, Shin Jeong(송신정) ORCID logo https://orcid.org/0000-0002-5789-854X
Lee, Sang-Eun(이상은) ORCID logo https://orcid.org/0000-0001-6645-4038
Chang, Hyuk-Jae(장혁재) ORCID logo https://orcid.org/0000-0002-6139-7545
Cho, In Jeong(조인정)
Heo, Ran(허란)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/175228
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links