0 932

Cited 7 times in

Cited 10 times in

Severe acute stent malapposition follow-up: 3-month and 12-month serial quantitative analyses by optical coherence tomography

DC Field Value Language
dc.contributor.authorHong, Sung-Jin-
dc.contributor.authorPark, Keun-Hee-
dc.contributor.authorAhn, Chul-Min-
dc.contributor.authorKim, Jung-Sun-
dc.contributor.authorKim, Byeong-Keuk-
dc.contributor.authorKo, Young-Guk-
dc.contributor.authorChoi, Donghoon-
dc.contributor.authorJang, Yangsoo-
dc.contributor.authorHong, Myeong-Ki-
dc.date.accessioned2020-02-11T06:50:10Z-
dc.date.available2020-02-11T06:50:10Z-
dc.date.created2021-03-18-
dc.date.issued2020-01-
dc.identifier.issn0167-5273-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/174870-
dc.description.abstractBackground: Optical coherence tomography (OCT) was used to assess serial changes in severe acute stent malapposition (ASM) after drug-eluting stent (DES) implantation. Methods: The maximal depth and axial lengths of ASM after DES implantation were serially quantified at percutaneous coronary intervention (PCI), and at 3 and 12-month follow-up, for 100 lesions in 96 patients. Severe ASM was defined as a maximal malapposed depth >= 400 mu m or maximal malapposed axial length >= 1 mm. Results: Of the 100 lesions, 23 lesions (23%) had a severe ASM depth at PCI. At 3 months, the maximal depth decreased to <400 mu m in 12 of 23 lesions (52%). At 12 months, the maximal depth further decreased to <400 mu m in 8 of the remaining 11 lesions (73%). Similarly, of 53 lesions (53%) with a severe ASM length at PCI, the maximal length decreased to 0 mm in 26 (49%) but remained severe in 17 lesions (32%) at 3 months. At 12 months, 9 of the 17 remaining lesions (53%) further decreased to 0 mm. The cut-off values for the maximal malapposed depth and length to predict the absence of stent malapposition at 12 months were 565 mu m at PCI and 165 mu m at 3 months, and were 2.7 mm at PCI and 0.1 mm at 3 months, respectively. Conclusion: Half of the severe ASM cases resolved within 3 months, and another half resolved during 3-12 months of follow-up. Our findings provide a better understanding of the time-dependent natural course of severe ASM using OCT. (C) 2019 Elsevier B.V. All rights reserved.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherElsevier-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF CARDIOLOGY-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF CARDIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleSevere acute stent malapposition follow-up: 3-month and 12-month serial quantitative analyses by optical coherence tomography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorHong, Sung-Jin-
dc.contributor.googleauthorPark, Keun-Hee-
dc.contributor.googleauthorAhn, Chul-Min-
dc.contributor.googleauthorKim, Jung-Sun-
dc.contributor.googleauthorKim, Byeong-Keuk-
dc.contributor.googleauthorKo, Young-Guk-
dc.contributor.googleauthorChoi, Donghoon-
dc.contributor.googleauthorJang, Yangsoo-
dc.contributor.googleauthorHong, Myeong-Ki-
dc.identifier.doi10.1016/j.ijcard.2019.06.075-
dc.relation.journalcodeJ01093-
dc.identifier.eissn1874-1754-
dc.identifier.pmid31279662-
dc.subject.keywordDrug-eluting stent-
dc.subject.keywordOptical coherence tomography-
dc.subject.keywordCoronary artery disease-
dc.contributor.alternativeNameKo, Young Guk-
dc.contributor.affiliatedAuthorHong, Sung-Jin-
dc.contributor.affiliatedAuthorPark, Keun-Hee-
dc.contributor.affiliatedAuthorAhn, Chul-Min-
dc.contributor.affiliatedAuthorKim, Jung-Sun-
dc.contributor.affiliatedAuthorKim, Byeong-Keuk-
dc.contributor.affiliatedAuthorKo, Young-Guk-
dc.contributor.affiliatedAuthorChoi, Donghoon-
dc.contributor.affiliatedAuthorJang, Yangsoo-
dc.contributor.affiliatedAuthorHong, Myeong-Ki-
dc.identifier.scopusid2-s2.0-85068265693-
dc.identifier.wosid000499685900016-
dc.citation.volume299-
dc.citation.startPage81-
dc.citation.endPage86-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF CARDIOLOGY, Vol.299 : 81-86, 2020-01-
dc.identifier.rimsid68663-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalClass1-
dc.subject.keywordAuthorDrug-eluting stent-
dc.subject.keywordAuthorOptical coherence tomography-
dc.subject.keywordAuthorCoronary artery disease-
dc.subject.keywordPlusELUTING STENTS-
dc.subject.keywordPlusSTRUT COVERAGE-
dc.subject.keywordPlusINTERVENTION-
dc.subject.keywordPlusAPPOSITION-
dc.subject.keywordPlusMECHANISMS-
dc.subject.keywordPlusOUTCOMES-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.