429 472

Cited 8 times in

Three-dimensional comparison of 2 digital models obtained from cone-beam computed tomographic scans of polyvinyl siloxane impressions and plaster models

Authors
 Jin-Yi Park  ;  Dasomi Kim  ;  Sang-Sun Han  ;  Hyung-Seog Yu  ;  Jung-Yul Cha 
Citation
 IMAGING SCIENCE IN DENTISTRY, Vol.49(4) : 257-263, 2019 
Journal Title
IMAGING SCIENCE IN DENTISTRY
ISSN
 2233-7822 
Issue Date
2019
Keywords
Cone-Beam Computed Tomography ; Dental Models ; Orthodontics
Abstract
Purpose:

This study was performed to evaluate the dimensional accuracy of digital dental models constructed from cone-beam computed tomographic (CBCT) scans of polyvinyl siloxane (PVS) impressions and cast scan models.

Materials and Methods:

A pair of PVS impressions was obtained from 20 subjects and scanned using CBCT (resolution, 0.1 mm). A cast scan model was constructed by scanning the gypsum model using a model scanner. After reconstruction of the digital models, the mesio-distal width of each tooth, inter-canine width, and inter-molar width were measured, and the Bolton ratios were calculated and compared. The 2 models were superimposed and the difference between the models was measured using 3-dimensional analysis.

Results:

The range of mean error between the cast scan model and the CBCT scan model was -0.15 mm to 0.13 mm in the mesio-distal width of the teeth and 0.03 mm to 0.42 mm in the width analysis. The differences in the Bolton ratios between the cast scan models and CBCT scan models were 0.87 (anterior ratio) and 0.72 (overall ratio), with no significant difference (P>0.05). The mean maxillary and mandibular difference when the cast scan model and the CBCT scan model were superimposed was 53 µm.

Conclusion:

There was no statistically significant difference in most of the measurements. The maximum tooth size difference was 0.15 mm, and the average difference in model overlap was 53 µm. Digital models produced by scanning impressions at a high resolution using CBCT can be used in clinical practice.
Files in This Item:
T201905412.pdf Download
DOI
10.5624/isd.2019.49.4.257
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers
Yonsei Authors
Yu, Hyung Seog(유형석) ORCID logo https://orcid.org/0000-0002-1275-5078
Cha, Jung Yul(차정열)
Han, Sang Sun(한상선) ORCID logo https://orcid.org/0000-0003-1775-7862
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/174731
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links